APAR status
Closed as program error.
Error description
WAS HTTP Plugin 8.5.5.16 on Windows Applying fixpack to WAS HTTP Plugin does not update the IIS_<webserver> copy of the binary: <PLG_INSTALL_ROOT>\bin\IIS_<webserver>\iisWASPlugin_http.dll It only updates the main binaries here: <PLG_INSTALL_ROOT>\bin\32bits\iisWASPlugin_http.dll <PLG_INSTALL_ROOT>\bin\64bits\iisWASPlugin_http.dll
Local fix
manually copy binary to IIS_webserver location
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server * **************************************************************** * PROBLEM DESCRIPTION: After applying a Fixpack, the IIS * * plugin dll isn't updated. * **************************************************************** * RECOMMENDATION: * **************************************************************** When a plugin fixpack is applied on Windows, the remote copies of the iisWASPlugin_http.dll aren't copied from the plugin-home/bin/32|64bits folder to the other iis_webserver folder.
Problem conclusion
There was a change made to the Fixpack processing that will make copies of the iisWASPlugin_http.dll from the plugin-home/bin/32|64bits folder to all of the iis_webserver named folders. The fix for this APAR is targeted for inclusion in fix pack 9.0.5.4 & 8.5.5.18. For more information, see 'Recommended Updates for WebSphere Application Server': http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PH21768
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-02-04
Closed date
2020-04-28
Last modified date
2020-04-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R850 PSY
UP
R900 PSY
UP