IBM Support

PH21715: DSP0204I INVALID VALUE FOR PARAMETER VOLLIST CAN BE ISSUED AND NOTIFY.IC CAN FAIL WHEN VOLUME NUMBER >= 2.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running MAINTAIN with ONLINE(Y) and the number of volumes
    in the VOLLIST of NOTIFY.IC is greater than or equal to 2,
    - Some of the volume serial numbers can be replaced with invalid
      values.
    - The message DSP0204I INVALID VALUE FOR PARAMETER VOLLIST can
      be issued and the NOTIFY.IC can fail with RC=12.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM IMS HALDB Toolkit V1.1.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: When running MAINTAIN with ONLINE(Y)    *
    *                      and the number of volumes in the        *
    *                      VOLLIST of NOTIFY.IC is greater than or *
    *                      equal to 2,                             *
    *                      - Some of the volume serial numbers can *
    *                        be replaced with invalid values.      *
    *                      - The message DSP0204I INVALID VALUE    *
    *                        FOR PARAMETER VOLLIST can be issued   *
    *                        and the NOTIFY.IC can fail with       *
    *                        RC=12.                                *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HTK creates the VOLLIST of NOTIFY.IC incorrectly when running
    MAINTAIN ONLINE(Y) and the number of volumes in the VOLLIST of
    NOTIFY.IC is greater than or equal to 2.
    

Problem conclusion

  • This APAR modifies the program so that HTK creates the VOLLIST
    of NOTIFY.IC correctly when running MAINTAIN ONLINE(Y) and
    the number of volumes in the VOLLIST of NOTIFY.IC is greater
    than or equal to 2.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH21715

  • Reported component name

    IMS HALDB TOOLK

  • Reported component ID

    5655DBU01

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-02-03

  • Closed date

    2020-02-27

  • Last modified date

    2020-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI68108

Modules/Macros

  • IHCULEV0 IHCXDSIN
    

Fix information

  • Fixed component name

    IMS HALDB TOOLK

  • Fixed component ID

    5655DBU01

Applicable component levels

  • R110 PSY UI68108

       UP20/02/29 P F002

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.