Closed as program error.
Error description
On Linux installations of IBM Rational Test Control Panel (RTCP), the Java heap size is not specified in the start script. Java will use the default allocation as defined by the system memory. This can result in RTCP running out of memory and crashing. This problem does not occur on Windows systems. WORKAROUND: The workaround is to allocate up to 2GB of memory. 1. Edit <RTCP install>/bin/setenv.sh. Typically: /opt/IBM/RationalTestControlPanel/bin/setenv.sh Append the following lines: JVM_ARGS=-Xmx2048m export JVM_ARGS 2. Restart RTCP 3. Use ps -ef to verify that the java process has -Xmx2048m as a parameter
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Linux users of IBM Rational Test Control Panel (RTCP) * **************************************************************** * PROBLEM DESCRIPTION: * * The start script for RTCP did not have a JVM heap allocation * * parameter. * * This could result in the upper limit for memory being too * * small, causing RTCP to exit. * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Rational Test Control Panel version 10.0.2.1 * ****************************************************************
Problem conclusion
Upgrade to IBM Rational Test Control Panel version 10.0.2.1 Java heap size is set to 2048MB
Temporary fix
Comments
APAR Information
APAR number
PH21412
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-01-24
Closed date
2020-03-20
Last modified date
2020-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"IBM Rational Test Workbench"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A00","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]