IBM Support

PH19482: THE DB_HOURS_SINCE_LASTIC IS NOT CORRECT AFTER THE IMAGE COPY JOB RUN.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Autonomics Director calculates DB_HOURS_SINCE_LASTIC incorrectly
    incorrectly. As the result, the following exception occurs:
    IRO4930I Hours since the last IC has reached or exceeded a
    threshold for the following data sets or area of xxxxxxxx
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS Tools Base for z/OS     *
    *                 Version 1 Release 6 (FMID: HAHN160) who use  *
    *                 the Autonomics Director.                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The value of DB_HOURS_SINCE_LASTIC is   *
    *                      not calculated correctly after image    *
    *                      copy job run. As the reuslt of this     *
    *                      error, DB_HOURS_SINCE_LASTIC exception  *
    *                      is occurred.                            *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR and      *
    *                 restart Autonomics Director server.          *
    ****************************************************************
    The module HKTSCTP1 calculates DB_HOURS_SINCE_LASTIC with
    current time and last image copy time. However, the current time
    is not current. As the result, the number of hours since the
    last image copy was taken is incorrect.
    

Problem conclusion

  • The module HKTSCTP1 has been modified to calculate the value of
    DB_HOURS_SINCE_LASTIC correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH19482

  • Reported component name

    IMS TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    160

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-11-20

  • Closed date

    2019-12-03

  • Last modified date

    2020-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI66735

Modules/Macros

  • HKTSCTP1
    

Fix information

  • Fixed component name

    IMS TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R160 PSY UI66735

       UP19/12/04 P F912

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160"}]

Document Information

Modified date:
14 December 2020