PH18794: 0C4 IN DFHSJJS WHEN KILL IS USED TO TERMINATE LIBERTY TASKS. 19/11/11 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A LIBERTY task is KILL'ed at a critical point in its processing
    and at this point, the task will get pulled back onto the QR
    TCB (from a T8 TCB which has by now been terminated). Error
    processing code is driven and attempts to reference an SJKE
    field which is addressed by SJKE_PTR.  SJKE_PTR is null it is
    only valid for a T8 TCB (which has now gone) and the 0c4 occurs.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All.                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend 0C4/AKEA at offset x'17A50' in    *
    *                      module DFHSJJS during recovery          *
    *                      processing.                             *
    ****************************************************************
    A Liberty task is terminated using the KILL command.  The task
    will attempt to unwind its calling stack and in doing so, is
    transferred to the QR TCB.  Control ends up in DFHSJJS which
    usually runs on the T8 TCB.  If the T8 TCB has gone then any
    reference to sjke_ptr may 0C4.
    
    Keywords: DFHSJ0001 msgDFHSJ0001 SJ0001 abend0C4 abends0C4 AKEA
    

Problem conclusion

  • UI66042 UI66045 UI66041
    
    The offending code has been modified and will now only be
    driven if there is an sjke_ptr.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH18794

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    000

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-11-04

  • Closed date

    2019-11-13

  • Last modified date

    2019-11-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI66400 UI66401 UI66402

Modules/Macros

  • DFHAPJVM DFHAXIS2 DFHCDJNI DFHSJBD  DFHSJDM  DFHSJDS  DFHSJDUF
    DFHSJIN  DFHSJIS  DFHSJIX  DFHSJJS  DFHSJL   DFHSJNA  DFHSJNR
    DFHSJNT  DFHSJRE  DFHSJRL  DFHSJRM  DFHSJRT  DFHSJSC  DFHSJSM
    DFHSJST  DFHSJTH  DFHSJTRI DFHSJXM  DFJ@H356 DFJ@H360 DFJ@H427
    DFJ@H467 DFJ@H468 DFJDTCOE DFJOUTRE DFJWLPBP DFJWLPPL
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R000 PSY UI66401

       UP19/11/30 P F911 {

  • R100 PSY UI66402

       UP19/11/30 P F911 {

  • R200 PSY UI66400

       UP19/11/30 P F911 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 November 2019