  • Closed as program error.

Error description

  • Unused Routines within program report is incorrect in AD
    5.1.0.3 when CICS START is used.
    

Local fix

  • N/A
    

Problem summary

  • Unused Routines are reported when using the EXEC CICS -> START
    statement.
    

Problem conclusion

  • Fixed with code changes related to the way the EXEC CICS ->
    START statement is handled by the COBOL compiler.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH18465

  • Reported component name

    APPL DISCOVERY

  • Reported component ID

    5737B1600

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-10-23

  • Closed date

    2021-12-17

  • Last modified date

    2021-12-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APPL DISCOVERY

  • Fixed component ID

    5737B1600

Applicable component levels

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRR9Q","label":"IBM Application Discovery"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510"}]

Document Information

Modified date:
18 December 2021