IBM Support

PH18400: MEMORY LEAK AFTER UI65330.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • APAR PH03715 was found to be in error when some new
    Duplicate Elimination parameters  are not set.  This error
    resulted in exhausting the negative SQLCODEs storage pool for
    the remainder of the collection interval
    

Local fix

  • Add the Duplicates Elimination parameters below to the CQMPARMS
    file
    THREAD_SQLCODE_DUPLICATES(10) -
    THREAD_SQLCODE_DUPLICATES_TIME(5) -
    DB2_SQLCODE_DUPLICATES(100) -
    DB2_SQLCODE_DUPLICATES_TIME(60) -
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM Db2 Query Monitor z/OS                   *
    *                 users of component                           *
    *                 - CQM ISPF                                   *
    *                 - SQL Codes                                  *
    *                 - Summaries                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: APAR PH03715 was found to be in error   *
    *                      when some new Duplicate Elimination     *
    *                      parameters are not set. This error      *
    *                      resulted in exhausting the negative     *
    *                      SQLCODEs storage pool for the remainder *
    *                      of the collection interval indicated by *
    *                      the message: CQM1213W SPACE IS FULL...  *
    *                      FOR SPACE - SQLCD.                      *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    APAR PH03715 / PTF UI65330 code works incorrectly in cases when
    only old parameters MAX_SQLCODE_DETAIL and MAX_SQLCODES supplied
    in the CQMPARMS. That causes processed SQLCD Detail records kept
    in storage until either interval completion or SQLCD pool
    depletion.
    

Problem conclusion

  • Code changed to fix this problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH18400

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    330

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-10-22

  • Closed date

    2019-11-26

  • Last modified date

    2019-11-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI66641

Modules/Macros

  • CQM$SQCI CQMMEACX CQMMEAPX CQMMEARX CQMMEASX CQMMEBCX CQMMEBPX
    CQMMEBRX CQMMEBSX CQMMECCX CQMMECPX CQMMECRX CQMMECSX CQMMSQLX
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R330 PSY UI66641

       UP19/11/28 P F911 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.3.0"}]

Document Information

Modified date: