A fix is available
APAR status
Closed as program error.
Error description
Incorrect runtime results: In AMODE64, DWARF data incorrectly shows the length of index items as 4-bytes instead of the correct value of 8-bytes. USERS AFFECTED: Users of Enterprise COBOL V6.3 performing a DWARF data dump on programs which contain index items which were compiled and ran in AMODE64. (LP(64) compiler option was specified during the compile). CONCLUSION: Compiler updated to provide AMODE checking for index item lengths provided to DWARF data dump. RECOMMENDATION TO CUSTOMER: Install the IBM provided PTF
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 performing a * * DWARF data dump on programs which contain * * index items which were compiled and run in * * AMODE64. (LP(64) compiler option was * * specified during the compile). * **************************************************************** * PROBLEM DESCRIPTION: Incorrect runtime results: In AMODE64, * * DWARF data incorrectly shows the * * length of index items as 4-bytes * * instead of the correct value of 8- * * bytes. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The Compiler was not using the specified AMODE setting when providing index item lengths to the DWARF data dump.
Problem conclusion
The compiler was changed to add the proper AMODE checking for index item lengths provided to DWARF data dump.
Temporary fix
Comments
APAR Information
APAR number
PH18205
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-17
Closed date
2019-11-26
Last modified date
2020-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI66646
UP19/12/04 P F912
R631 PSY UI66647
UP19/12/04 P F912
R632 PSY UI66648
UP19/12/04 P F912
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023