A fix is available
APAR status
Closed as program error.
Error description
Testing 64-bit mode, COBOL program receives a s0c4 at execution time on a SET ADDRESS statement.
Local fix
Compile and execute in 31-bit mode
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.3 compiling and * * running programs that set the addresses of * * the CVT-BLOCK and SMF-BLOCK to pointers in * * AMODE64 (LP(64) compiler option was * * specified during the compile). * **************************************************************** * PROBLEM DESCRIPTION: ABEND: Compiler fails with an S0C4 * * error at runtime on SET ADDRESS * * statement when attempting to set * * CVT-BLOCK and SMF-BLOCK to pointers. * **************************************************************** * RECOMMENDATION: Apply the provided PTF and recompile with * * affected pointers changed to pointer-32 * **************************************************************** Addresses of CVT-BLOCK AND SMF-BLOCK are fixed as 4-byte addresses by System Z architecture. Setting 8-byte pointers to these addresses fills the high word of the pointer with random values which results in the S0C4 ABEND.
Problem conclusion
The compiler was changed so that Pointer-32 data-items are used correctly to allow for proper set address statement behavior.
Temporary fix
Comments
APAR Information
APAR number
PH18124
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-15
Closed date
2019-11-26
Last modified date
2020-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI66646
UP19/12/04 P F912
R631 PSY UI66647
UP19/12/04 P F912
R632 PSY UI66648
UP19/12/04 P F912
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]