A fix is available
APAR status
Closed as program error.
Error description
If the storage returned via GETMAIN has not been cleared by z/OS, Advanced ACBGEN utility may cause a problem.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users * * who use the Advanced ACBGEN utility. * **************************************************************** * PROBLEM DESCRIPTION: This APAR fixes the Advanced ACBGEN * * utility not to cause a problem when * * the storage returned via GETMAIN has * * not been cleared by z/OS. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** The Advanced ACBGEN uses some storage via GETMAIN without clearing. If the storage has not been cleared by z/OS, the Advanced ACBGEN utility may cause a problem like ABENDS0C4. This APAR fixes the Advanced ACBGEN utility to clear the storage returned via GETMAIN.
Problem conclusion
The following modules have been changed to fix the above problem: FABQCHAN,FABQDIRX,FABQDRIV,FABQLMGR,FABQMBRX, FABQPARS,FABQSPAC,FABQSYSI
Temporary fix
Comments
APAR Information
APAR number
PH18031
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-15
Closed date
2019-10-29
Last modified date
2022-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI66117
Modules/Macros
FABQCHAN FABQDIRX FABQDRIV FABQLMGR FABQMBRX FABQPARS FABQSPAC FABQSYSI
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R220 PSY UI66117
UP19/10/31 P F910
Fix is available