IBM Support

PH17487: KO2Z999E OM01 V540 SERVICE ERROR SSM=OMPECBA /OMPEOBC ABEND= S0C4 RSN=0000003B MODE=ABEND

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • KO2Z999E OM01 V540 Service error SSM = OMPECBA / OMPEOBC ABEND=
    S0C4 RSN = 0000003B MODE = ABEND
    
    DUMP TITLE=OM01 SERVER ERROR CID=DB2OM STC=CANSO2  SSM=OMPECBA
          /OMPEOBC ABEND= S0C4 RSN=0000003B MODE=ABEND
    
    ABEND0C4-3B OMPECBC + X'2E8' resolving lock resource names on
    remote DB2 with DBID > 32767
    
    ABEND0C4 ABENDS0C4 0C4
    
    dbid has gone negative which you can prove by running this query
    SELECT DBID, HEX(DBID) AS DBIDX, NAME
      FROM SYSIBM.SYSDATABASE
      WHERE DBID < 0
      ORDER BY DBID
    
    This also effects Object Analysis such that on screen ZOJAS
    tablespaces and indexspaces will report as 0. On screen ZOJA1
    TYPE will report as UNDT - undetermined
    

Local fix

  • Apply PTF when available
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM                *
    *                 users of component                           *
    *                 OMEGAMON Collector                           *
    *                 Classic Interface                            *
    *                 ATF                                          *
    *                 Object Analysis                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Main issue: ABEND0C4 OMPECBC+X'2E8'     *
    *                      During remote lock resource resolution  *
    *                      for database with negative DBID. ABEND  *
    *                      occurs in collector running on REMOTE   *
    *                      system, not where the CLASSIC session   *
    *                      is running.                             *
    *                      INCORROUTS -                            *
    *                      Classic Interface - ZLOCKC, XLOCKO and  *
    *                      ZLOCKW all show DBID/OBID if DBID is    *
    *                      negative.                               *
    *                      ATF - When collection is in memory,     *
    *                      DBID/OBID shown if DBID negative.       *
    *                      Object Analysis - ZOJAS shows the       *
    *                      number of allocated objects, but zero   *
    *                      For both number of tablespaces and      *
    *                      number of indexes.                      *
    *                      ZOJA2 shows UNDT for object type.       *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    DBID/OBID resolution was incorrectly processing the negative
    DBID, resulting in an ABEND in one case, and INCORROUTS in the
    other cases.
    

Problem conclusion

  • DBID/OBID resolution logic corrected to accept negative DBIDs
    without ABENDING or failing to resolve names.
    
    Search Keywords:
    INCORROUT
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH17487

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-09-27

  • Closed date

    2020-01-02

  • Last modified date

    2020-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI67211

Modules/Macros

  • KO2ED012 KO2ED01K KO2ED01S KO2EOJS2 KO2EOJSK KO2EOJSS KO2XLKD2
    KO2XLKDK KO2XLKDS KO2ZOBC2 KO2ZOBCK KO2ZOBCS KO2ZOBD2 KO2ZOBDK
    KO2ZOBDS
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R540 PSY UI67211

       UP20/01/04 P F001

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 February 2020