A fix is available
APAR status
Closed as program error.
Error description
QSAM OPEN under LP(64) may trigger IEC130I message incorrectly for AMODE 64
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6R3, compiling * * and running programs with the LP(64) option * * and use COBOL sequential files. * **************************************************************** * PROBLEM DESCRIPTION: Message IEC130I may be issued during * * the processing of COBOL OPEN statement * * when the file is QSAM. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** There was an error in message processing for the COBOL OPEN statement, causing message IEC130I to be issued when there was no error in the QSAM file OPEN operation. The OPEN statement was actually successful. Fixcat keyword COB0603T/K
Problem conclusion
The incorrect message processing has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PH17325
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-09-24
Closed date
2019-10-24
Last modified date
2019-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI66035
Modules/Macros
CELQSG04 CELQV004 IGZCER4 IGZCEV4 IGZCMGEN IGZCMGUE IGZLLIBV IGZQAPI IGZQCDA IGZQINPL IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXPK2
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020