Error description
When using DWC 9.4 FP4 Show Plan function the following abend 0C4 is seen in the controller: SYSTEM COMPLETION CODE=0C4 REASON CODE=00000010 PSW AT TIME OF ERROR 078D3000 8F0E38B4 ILC 6 INTC 10 ACTIVE LOAD MODULE OFFSET=0008433C NAME=EQQGSBEX DATA AT PSW 0F0E38AE - 99F441E3 D3A3D200 E000F000 AR/GR 0: 00000000/00000490 1: 00000000/00000010 2: 01010039/00000000 3: 00000000/00000001 4: 00000000/00000002 5: 00000000/0000000A 6: 00000000/001D2000 7: 00000000/0F0E4380 8: 00000000/0F0E5380 9: 00000000/0F0E6380 A: 00000000/0FC46120 B: 00000000/8F0E3380 C: 00000000/00000001 D: 00000000/001D3F80 E: 00000000/001D4324 F: 00000000/E3E6E2E3 . Abend is at EQQGSVI1+534 at UI55005 level . Message in controller MLOG: EQQG004E SUBTASK GS EXECUTOR 01 ABENDED, IT IS RESTARTED AT CLEANUP . When controller is shut down this message is seen: EQQZ024I STILL ALLOCATED AREA, STAMP: EQQGSVIE
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All TWS for z/OS 910 USERS * * All TWS for z/OS 920 USERS * * All IWS for z/OS 930 USERS * * All zWS for z/OS 950 USERS * * FUNCTION=GS * **************************************************************** * PROBLEM DESCRIPTION: 0C4 in the controller when the DWC 9.4 * * FP4 Show Plan View function is used * * and "range of date" is only specified. * * The boxes predecessors and successors * * are checked. * **************************************************************** 0C4 in the controller when the DWC 9.4 FP4 Show Plan View function is used and "range of date" is only specified. The boxes predecessors and successors are checked.
Problem conclusion
Changed the code to allocate correctly the pointer to the range of date when the search occur only for the range of dates.
Temporary fix
Comments
APAR Information
APAR number
PH13127
Reported component name
TIV WRKLD SCHD
Reported component ID
5697WSZ01
Reported release
932
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-06-10
Closed date
2019-06-24
Last modified date
2020-11-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI63822 UI63823 UI63824 UI63825
Modules/Macros
EQQGSVI1
Fix information
Fixed component name
TIV WRKLD SCHD
Fixed component ID
5697WSZ01
Applicable component levels
R912 PSY UI63822
UP19/07/12 P F907
R922 PSY UI63824
UP19/07/12 P F907
R932 PSY UI63823
UP19/07/12 P F907
R952 PSY UI63825
UP19/07/12 P F907
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"932"}]
Document Information
Modified date:
13 November 2020