A fix is available
APAR status
Closed as program error.
Error description
CORRNUM value may be incorrect if CORRID_TRANSLATION parameter in CQMPARMS is specified.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IBM Db2 Query Monitor z/OS * * users of component * * - ISPF Client * * - Summaries * * - CAE Navigation/Drill downs/Formatting * * - CQM Data Collector * **************************************************************** * PROBLEM DESCRIPTION: 1. Many messages FEC804E: 00F30056 in * * Query Montior joblog when Db2 is in * * maint mode. * * 2. CORRNUM value is incorrect if * * CORRID_TRANSLATION parameter is * * specified. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** 1. When Db2 is in maintenance mode, Query Monitor can not connect to it. But Query Monitor checks every ten seconds for Db2 availability and issues message 'FEC804E: 00F30056: Unexpected reason code from call attach facility', which corresponds to MAINT mode. 2. Due to incorrect logic, CORRNUM was taken from next position to the specified one via CORRID_TRANSLATION parameter.
Problem conclusion
1. Logic is changed to issue message only during first attempt to connect to Db2 in MAINT mode. 2. Logic is changed to use correct position according to CORRID_TRANSLATION parameter. Search Keywords: MANY MESSAGES FEC804E 00F30056 DB2 MAINT MODE CORRID_TRANSLATION CORRNUM
Temporary fix
Comments
APAR Information
APAR number
PH12612
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-28
Closed date
2019-09-13
Last modified date
2019-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CQM#BCMX CQM#PARM CQM#SSMN CQM$SLIP
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R330 PSY UI65315
UP19/09/17 P F909
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.3.0"}]
Document Information
Modified date:
30 March 2021