IBM Support

PH12114: IGYDI5125-U THE COMPILATION WAS TERMINATED DUE TO A COMPILER ERROR IN PHASE ID: "IGYCDIAG"

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IGYDI5125-U   The compilation was terminated due to a compiler
    error in phase id:  "IGYCDIAG"
    

Local fix

  • compiling at OPT(0) or turning off NUMCHECK(BIN), or by running
    the program with NUMCHECK(BIN,MSG) turned on and fixing the
    invalid data.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling     *
    *                 programs with NUMCHECK(BIN) containing       *
    *                 invalid data that is detectable at compile-  *
    *                 time.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler abend with message             *
    *                      MSGIGYDI5125-U The compilation was      *
    *                      terminated due to a compiler            *
    *                      error in phase id: "IGYCDIAG".          *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    The compiler was generating NUMCHECK(BIN) messages where the
    message text, containing the name of the data item and line and
    statement number on which the invalid data was detected,
    exceeded an internal limit on the length for message text.
    

Problem conclusion

  • The NUMCHECK(BIN) message text was shortened so that the final
    text of a message would fit within the compiler's internal
    limit.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH12114

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-05-15

  • Closed date

    2019-05-23

  • Last modified date

    2019-06-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH13064

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI63207

       UP19/05/30 P F905

  • R621 PSY UI63208

       UP19/05/30 P F905

  • R622 PSY UI63209

       UP19/05/30 P F905

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023