A fix is available
APAR status
Closed as program error.
Error description
You are using the WUI View Editor to add filter criteria to a field on a view. You receive the following error message in the WUI . EYUVE1001E An unrecoverable editor error has occurred (Screen number 42) . In the AUX trace from the WUI region, you see the following exceptions: . TASK MTD PREV TRAN OBJ LEVL PT-ID DEBUG SEQUENCE 12345 VONV VOLV COVA SIM EXCP 19 BADGTDFV 1 12345 VOLV VOBV COVA SIM EXCP 39 BADVONV 2 12345 VOBV VFXE COVA SIM EXCP 108 BADVOLV 3 12345 VFXE VFXC COVA SIM EXCP 510 badVobv 4 12345 VFXC VE2A COVA SIM EXCP 502 badVfxe1 5 12345 VE2A VERT COVA SIM EXCP 911 6ColFail 6 12345 VERT VGAR COVA SIM EXCP 1 ScrnFail 7 . The first entry with BADGTDFV shows data traced as: . OBJECT LEN: 000008 0 - C3C9C3E2 D9C7D540 *CICSRGN ATTRIB LEN: 00000C 0 - C1C3D8E2 E3C1E3E4 E2404040 *ACQSTATUS RESPONSE LEN: 000004 0 - 00000404 *.... REASON LEN: 000004 0 - 0000051E *.... . The RESPONSE/REASON interprets to be: . RESP 1028 - INVALIDPARM RSN 1310 - ATTRIBUTE . . In the above trace, the OBJECT seen is not the CPSM Base Table that was involved in the filter being set. The CPSM WUI is incorrectly using the wrong table name, and thus the RESPONSE / REASON combination is returned. . . .Additional Symptom(s) Search Keyword(s): KIXREVSCB
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CPSM V5R3M0, V5R4M0 and V5R5M0. * **************************************************************** * PROBLEM DESCRIPTION: When WUI View Editor is used to add a * * filter to a link between a field on a * * view and a target view in different * * view set, the following error message * * shows on the WUI view: * * * * EYUVE1001E An unrecoverable editor * * error has occurred * * (Screen number 42) * * * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves * * PH09390, all WUI regions must be recycled to * * pick up the new code. Note that the * * restarts do not need to occur at the same * * time. * **************************************************************** When WUI View editor is used to customize an existing view, and create a link from a field on the view to a target view in a different view set, a field of the target view could be selected as a filter to minimize the records being displayed on the target view. When a field of the target view was chosen on the WUI View Editor, method EYU0VE2A is driven to populate the screen containing all the information related to that filter, including attribute filter operator, filter value etc. The filter value can be either a fixed CVDA value or an attribute value from the same view. To retrieve the CVDA attribute value for the filter, an EXEC CPSM GETDEF request was sent over to the CMAS. However, the resource name is not set properly. As a result, the validation of the attribute and the resource fails, and error message EYUVE1001E was displayed.
Problem conclusion
Module EYU0VE2A has been updated to set the resource properly.
Temporary fix
Comments
APAR Information
APAR number
PH09390
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
00M
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / CST / Xsystem
Submitted date
2019-03-06
Closed date
2019-04-18
Last modified date
2019-05-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI62561 UI62562 UI62563
Modules/Macros
EYU0VE2A
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R00M PSY UI62561
UP19/04/19 P F904
R10M PSY UI62562
UP19/04/19 P F904
R20M PSY UI62563
UP19/04/24 P F904
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
07 May 2019