A fix is available
APAR status
Closed as program error.
Error description
The following 0c4-4 abend occurs at the time of CHINIT shut down: DUMP TITLE=CSQ2,ABN= 0C4-00000004,C=MQ900.911.CHIN,M=CSQXJST ,LOC=CSQXJST .CSQXJST +0469A . Additional Keywords: ABEND0C4 ABENDS0C4 S0C4 S00C4
Local fix
Configuring the queue manager's EXITTCB parameter in CSQ6SYSP to be a non-zero value should prevent the abend from occurring.
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM MQ for z/OS Version 9 * * Release 1 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: ABEND 0C4-4 in CSQXJST at shutdown when * * EXITTCB=0. * **************************************************************** ABEND0C4 in CSQXJST during shutdown when EXITTCB=0 is specified on the CSQ6SYSP macro in CSQ4ZPRM. The failure occurs when testing whether the cluster workload exit monitor task CSQXRFEA should be re-attached after failing earlier because no server tasks were specified on the EXITTCB parameter. The lack of any server tasks to process cluster workload exit requests is reported during startup with message CSQV452I 'Cluster workload exits not available'. Additional keywords: CSQX_ABEND_CLWX_NO_SVR_TASKS
Problem conclusion
Module CSQXJST has been updated so that it will not attempt to re-attach CSQXRFEA if it previously failed because no server tasks were available.
Temporary fix
Comments
APAR Information
APAR number
PH09248
Reported component name
IBM MQ Z/OS V9
Reported component ID
5655MQ900
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-03-03
Closed date
2019-05-16
Last modified date
2019-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI63058
Modules/Macros
CSQXJST
Fix information
Fixed component name
IBM MQ Z/OS V9
Fixed component ID
5655MQ900
Applicable component levels
R100 PSY UI63058
UP19/06/06 P F906
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
01 July 2019