PH08915: XASUPPORT=NONE FOR FLOWTYPE "ECISYNCONRETURN"

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • The CICS TG resource adapter currently provides the option for
    XA to be "on" and "off".
    
    In case xaSupport = off   The FlowType will be "ExtendedModeEci"
    In case xaSupport = on    The FlowType will be "XAFlow"
    
    
    A xaSupport = none option will be introduced for the CTG
    resource adapter (as per RFE 67167).
    
    In case xaSupport = none  The FlowType will be "EciSynconreturn"
    

Local fix

  • Not available
    

Problem summary

  • Support of NoTransaction as TransactionSupportLevel  in CICS TG
    resource adapter.
    
    The CICS TG resource adapter currently provides the option for
    XA to be "on" and "off".
    
    In case xaSupport = off   The FlowType is "ExtendedModeEci"
    In case xaSupport = on    The FlowType is "XAFlow"
    
    
    A xaSupport = none option is introduced for the CTG
    resource adapter.
    
    In case xaSupport = none  The FlowType is "EciSynconreturn"
    

Problem conclusion

  • CICS TG resource adapter is changed to address the issue.
    

Temporary fix

  • N/A
    

Comments

APAR Information

  • APAR number

    PH08915

  • Reported component name

    CICS TRNS GATE

  • Reported component ID

    5724I8103

  • Reported release

    910

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-02-26

  • Closed date

    2019-08-28

  • Last modified date

    2019-08-28

  • APAR is sysrouted FROM one or more of the following:

    PH06220

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS TRNS GATE

  • Fixed component ID

    5724I8103

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMJ2","label":"CICS Transaction Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
15 August 2024