PH08084: UNSTRING STATEMENT READS PAST THE END OF SENDING FIELD CAUSING FALSE MATCHES WITH DELIMITER VALUE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • UNSTRING statement reads past the end of sending field causing
    false matches with DELIMITER value.  UNSTRING may put one extra
    byte into the DELIMITER field.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V5 and later       *
    *                 releases who are using UNSTRING statement.   *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The COBOL runtime UNSTRING routine      *
    *                      does one extra delimiter check beyond   *
    *                      the end of the sending field, causing   *
    *                      incorrect UNSTRING result.              *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    *                                                              *
    ****************************************************************
    During UNSTRING processing, the COBOL runtime fails to check for
    the remaining length of the sending field, and uses dirty byte
    values following the end of the field to do one extra delimiter
    comparison before stopping. This could lead to erroneous
    UNSTRING result.
    
    FIXCAT keyword: COB0501T/K  COB0502T/K  COB0601T/K  COB0602T/K
    

Problem conclusion

  • The COBOL Runtime is corrected to stop properly at the end of
    the sending field when the remaining field length is too short
    to do delimiter comparison.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH08084

  • Reported component name

    LE ENT COBOL LI

  • Reported component ID

    568819812

  • Reported release

    7A0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-02-01

  • Closed date

    2019-03-14

  • Last modified date

    2019-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH09481 UI61878

Modules/Macros

  • IGZCEV4  IGZLLIBV IGZXAPI  IGZXCDA  IGZXDMR
    IGZXD24  IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE
    IGZXLPKF IGZXLPKG IGZXPK2
    

Fix information

  • Fixed component name

    LE ENT COBOL LI

  • Fixed component ID

    568819812

Applicable component levels

  • R7A0 PSY UI61878

       UP19/03/29 P F903

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020