A fix is available
APAR status
Closed as program error.
Error description
A change to the generation of long relative branches to correctly reflect code usage with code coverage tools was included in the October 2018 v6.1 PTF (September 2018 v6.2 PTF). This change may cause an infinite recursion in the code generator, resulting in the compiler ending with return code 16, but no specific compiler diagnostic. The joblog will show a U4088-807 due to stack memory exhaustion. The above the line storage high water mark (IEF032I EXT: value) will also be high.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling * * programs at OPT(1|2) with PERFORM VARYING * * statement. * **************************************************************** * PROBLEM DESCRIPTION: Compiler aborts with USER COMPLETION * * CODE=4088 REASON CODE=00000807 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** An incorrectly initialized variable in the compiler could cause the compiler to run out of memory.
Problem conclusion
Compiler was updated to properly initialize the variable causing the issue.
Temporary fix
Comments
APAR Information
APAR number
PH07211
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-01-11
Closed date
2019-01-14
Last modified date
2019-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R620 PSY UI60666
UP19/01/30 P F901
R621 PSY UI60667
UP19/01/30 P F901
R622 PSY UI60668
UP19/01/30 P F901
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]