A fix is available
APAR status
Closed as program error.
Error description
User may see incorrect, large values, displayed for Log Write IO Delay on Structural Summaries panel.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IBM Db2 Query Monitor for * * z/OS users of ISPF client * **************************************************************** * PROBLEM DESCRIPTION: Incorrect values displayed for * * Structural Summaries, Log Write IO * * Delay. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Values of Log Write IO Delay in Structural Summaries on panel CQM$SUMB may be unreasonably huge for Db2 v11 and above due to incorrect calculation.
Problem conclusion
Correction of calculation for Log Write IO Delay. Search Keywords: Log Write IO Delay
Temporary fix
Comments
APAR Information
APAR number
PH06855
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
330
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-12-31
Closed date
2019-06-20
Last modified date
2019-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI63750
Modules/Macros
CQMOREDX
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
R330 PSY UI63750
UP19/06/22 P F906
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.3.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: