A fix is available
APAR status
Closed as program error.
Error description
Running LOAD with PACING=1.0 and MAXWAIT 00:00:15 (or any small MAXWAIT) causes PACING not to wait (or pace as expected). PACING < 1.0 and PACING > 1.0 does work fine. Also PACING=1.0 with MAXWAIT or 10 minutes or more also works fine. This is a duplicate of a canceled APAR PI89180. It has been determined that this needed to be addressed after all.
Local fix
Change PACING to be more or less than 1.0 or adjust MAXWAIT as described above.
Problem summary
**************************************************************** * USERS AFFECTED: Users of QCF 3.2 * **************************************************************** * PROBLEM DESCRIPTION: Specifying PACING=1.0 did not reinsert * * the data set at the same rate that they * * were originally inserted. The duration * * of reinsertion was much quicker, or * * twice as long. * **************************************************************** * RECOMMENDATION: Install the APAR to have pacing work as * * expected and set in control cards * **************************************************************** Specifying PACING=1.0 did not reinsert the data set at the same rate that they were originally inserted. The duration of reinsertion was much quicker, or twice as long as the original time. END statement issues an error.
Problem conclusion
Install the APAR to receive the fix to the PACING statement and END statement.
Temporary fix
Comments
APAR Information
APAR number
PH06388
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-12-11
Closed date
2018-12-16
Last modified date
2019-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI60285
Modules/Macros
IQCSEL61 IQCSELCT IQCXCTRL IQCXPACE
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI60285
UP18/12/19 P F812
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 January 2019