A fix is available
APAR status
Closed as program error.
Error description
Incorrect output: Although SSRANGE code is generated for reference modifications, the IGYSC2253-W warning message is not produced unless the program also includes at least one table (no actual table access is required).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.1 compiling * * programs with the RULES(NOLAXPERF) and * * SSRANGE compiler options. * **************************************************************** * PROBLEM DESCRIPTION: Incorrect output: Although SSRANGE code * * is generated for reference * * modifications, the IGYSC2253-W warning * * message is not produced unless the * * program also includes at least one * * table (no actual table access is * * required). * **************************************************************** * RECOMMENDATION: Apply the IBM provided PTF. * **************************************************************** When the RULES(NOLAXPERF) and SSRANGE compiler options were specified, the compiler based its decision to generate message IGYSC2253-W solely on the presence of tables in the data division, even though SSRANGE code can be generated for reference modifications as well.
Problem conclusion
The compiler was modified so that it also keeps track of reference modifications, as well as table definitions, when deciding whether to produce the IGYSC2253-W warning message for RULES(NOLAXPERF) and SSRANGE.
Temporary fix
Comments
APAR Information
APAR number
PH06314
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-12-09
Closed date
2018-12-12
Last modified date
2019-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCCBE IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R610 PSY UI60241
UP18/12/18 P F812
R611 PSY UI60242
UP18/12/19 P F812
R612 PSY UI60243
UP18/12/19 P F812
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023