IBM Support

PH05465: THE COMPARE MAY BE INCORRECTLY EVALUATED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ERROR DESCRIPTION:
    USERS AFFECTED: Users of Enterprise COBOL Vx.x compiling
    programs that compare several pairs of data
    items in one IF statement where the two
    sets
    of data items are sequential and contiguous
    but at least one of the pairs of data items
    has differing sizes.
    
    PROBLEM DESCRIPTION: The compare may be incorrectly
    evaluated
    
    WORKAROUND/CIRCUMVENTION: Compile at OPT(0)
    
    RECOMMENDATION TO CUSTOMER: Apply the provided PTF
    
    PROBLEM SUMMARY: The optimizer may sometimes group sequential
    compares of data
    items into one larger compare. If one or more pairs have
    differing sizes (taking up a different amount of bytes), at
    least one additional byte will incorrectly be compared by the
    shorter sequence. As this byte is from a different data item,
    not intended to be compared at all, the result of the compare
    will be incorrect.
    
    CONCLUSION: The optimizer was fixed to only group sequential
    compares into
    one compare if each pair of data items has the same size.
    

Local fix

  • WORKAROUND/CIRCUMVENTION: Compile at OPT(0)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling     *
    *                 programs that compare several pairs of data  *
    *                 items in one IF statement where the two      *
    *                 sets of data items are sequential and        *
    *                 contiguous but at least one of the pairs of  *
    *                 data items has differing sizes.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: The compare may be incorrectly          *
    *                      evaluated.                              *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    The optimizer may sometimes group sequential compares of data
    items into one larger compare. If one or more pairs have
    differing sizes (taking up a different amount of bytes), at
    least one additional byte will incorrectly be compared by the
    shorter sequence. As this byte is from a different data item,
    not intended to be compared at all, the result of the compare
    will be incorrect.
    

Problem conclusion

  • The optimizer was fixed to only group sequential compares into
    one compare if each pair of data items has the same size.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH05465

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-11-19

  • Closed date

    2019-01-14

  • Last modified date

    2019-02-02

  • APAR is sysrouted FROM one or more of the following:

    PH05455

  • APAR is sysrouted TO one or more of the following:

    UI60666 UI60667 UI60668

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI60666

       UP19/01/30 P F901

  • R621 PSY UI60667

       UP19/01/30 P F901

  • R622 PSY UI60668

       UP19/01/30 P F901

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: