IBM Support

PH04494: THE ENTERPRISE COBOL V6.2 COMPILER COULD ABEND DURING COMPILE TIME IN COMPILER PROGRAM MODULE IGYCDMAP

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • With some COBOL source programs, the compiler would ABEND
    during compile time when generating ADATA.  Specifically, the
    COBOL source program would need to contain sufficiently long
    IV data in a Data Description Entry such that the generated
    ADATA record is required to be continued onto another, new
    record.  During this processing, an internal logic error
    would result in an ABEND during compile time.
    

Local fix

  • Turning off the ADATA compiler option will prevent the compiler
    ABEND, but will not produce ADATA output.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling      *
    *                 programs with compiler option ADATA          *
    *                 where the Initial Value (IV) Pairs data      *
    *                 within a Symbol Record ('0042'X) is          *
    *                 sufficiently long to cause a continuation    *
    *                 into a new ADATA record.                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Enterprise COBOL V6.2 compiler      *
    *                      would ABEND during compile time in      *
    *                      compiler program module IGYCDMAP.       *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    With some COBOL source programs, the compiler would ABEND
    during compile time when generating ADATA. Specifically, the
    COBOL source program would need to contain sufficiently long
    IV data in a Data Description Entry such that the generated
    ADATA record is required to be continued onto another, new
    record. During this processing, an internal logic error
    would result in an ABEND during compile time.
    

Problem conclusion

  • The compiler was updated with a fix for the ABEND. It will now
    properly generate continued ADATA records in the aforementioned
    situation.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH04494

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-10-24

  • Closed date

    2018-11-22

  • Last modified date

    2018-12-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH06041 PH06056

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI
    IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT
    IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4
    IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI
    IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI59885

       UP18/11/29 P F811

  • R621 PSY UI59886

       UP18/11/29 P F811

  • R622 PSY UI59887

       UP18/11/29 P F811

  • R62H PSY UI59888

       UP18/11/29 P F811

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023