IBM Support

PH03733: INCORRECT RESULT: THE SECOND PACKED-DECIMAL DATA ITEM CONTAINS ONLY AS MANY DIGITS AS THE USAGE DISPLAY DATA ITEM.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling
    programs with ZONEDATA(NOPFD|MIG), OPT(1|2), and ARCH(12) that
    move data from a PACKED-DECIMAL data item to a USAGE DISPLAY
    data item with fewer digits, and then from the first
    PACKED-DECIMAL data item to another with more digits than the
    USAGE DISPLAY data item.
    
    The compiler was incorrectly truncating to the size of the USAGE
    DISPLAY data item in a register that was reused as the source
    for the second MOVE statement.
    

Local fix

  • Compile at OPT(0).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 compiling     *
    *                 programs with ZONEDATA(NOPFD|MIG),           *
    *                 OPT(1|2), and ARCH(12) that move data        *
    *                 from a PACKED-DECIMAL data item to a         *
    *                 USAGE DISPLAY data item with fewer           *
    *                 digits, and then from the first              *
    *                 PACKED-DECIMAL data item to another          *
    *                 with more digits than the USAGE DISPLAY      *
    *                 data item.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect result: the second PACKED-    *
    *                      DECIMAL data item contains only as      *
    *                      many digits as the USAGE DISPLAY data   *
    *                      item.                                   *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    The compiler was incorrectly truncating to the size of the USAGE
    DISPLAY data item in a register that was reused as the source
    for the second MOVE statement.
    

Problem conclusion

  • The compiler was fixed to use a new register when truncating in
    the first MOVE statement.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH03733

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-10-05

  • Closed date

    2018-11-22

  • Last modified date

    2018-12-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI
    IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT
    IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4
    IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI
    IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI59885

       UP18/11/29 P F811

  • R621 PSY UI59886

       UP18/11/29 P F811

  • R622 PSY UI59887

       UP18/11/29 P F811

  • R62H PSY UI59888

       UP18/11/29 P F811

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023