Error description

  • 1).  Pending response/Waiting reply total is calculated
    incorrectly where a client has set a TIMER value of 'E9' on an
    ACK request. In this situation there is no read following the
    ACK so it was being incorrectly counted as a message waiting on
    OTMA, and the predicted status in active sessions was showing
    as 'P002 - Waiting for reply from datastore'
    2). Pending response/Waiting reply total is calculated
    incorrectly where a client has set the IRM_F5 flag to AUTO,
    DEFAULT or SWAIT for a RTPIPE command. In these situations the
    messages were incorrectly counted as a message waiting on OTMA
    and the predicted status in active sessions was showing as
    'P002 - Waiting for reply from datastore'
    The IMS Connect Extensions v3.1 forward-fit for this APAR is
    PH09156.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extensions V2.4         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Pending response/Waiting reply total    *
    *                      showing higher value than expected.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    1. Pending response/Waiting reply total is calculated
       incorrectly where a client has set a TIMER value of 'E9' on
       an ACK request.  In this situation there is no read following
       the ACK so it was being incorrectly counted as a message
       waiting on OTMA, and the predicted status in active sessions
       was showing as 'P002 - Waiting for reply from datastore'.
    
    2. Pending response/Waiting reply total is calculated
       incorrectly where a client has set the IRM_F5 flag to AUTO,
       DEFAULT or SWAIT for a RTPIPE command. In these situations
       the messages were incorrectly counted as a message waiting on
       OTMA and the predicted status in active sessions was showing
       as 'P002 - Waiting for reply from datastore'.
    

Problem conclusion

  • 1. Corrected Pending response/Waiting reply counts to exclude
       situations where an ACK Message has been sent to OTMA with
       a TIMER value of 'E9'. For this situation the predicted
       status in active sessions now shows as
       'P013 - Waiting in read prepare process'.
    
    2. Corrected Pending response/Waiting reply counts to exclude
       situations where an RTPIPE type request of AUTO, DEFAULT or
       SWAIT are found. For these situations the predicted status in
       active sessions now shows as 'P043 -
       'P043 - RTPIPE waiting on asynchronous output'.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH03211

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    240

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-09-24

  • Closed date

    2019-03-05

  • Last modified date

    2019-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI61672

Modules/Macros

  • CEX#ABOU CEXCONS  CEXCONSS CEXCSKT  CEXEVTPR
    CEXEVTSR CEXEVT01 CEXEVWTR CEXI09   CEXMAIN  CEXOPDRV CEXPRED0
    CEXPRED1 CEXPUBMN CEXPUDRV CEXRXADR CEXR168  CEXSALUT CEXTECL
    CEXTPXML H28S240J
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R240 PSY UI61672

       UP19/03/08 P F903