A fix is available
APAR status
Closed as program error.
Error description
When compiling more than one compile unit in the same compiler invocation (known as a batch compile), the compiler fails to reset the working-storage and compiler static sizes to zero between compile units; the sizes become cumulative over the batch. This is evident from the LIST and MAP outputs. The PPA4 "Entry Point Constants" entry for working-storage length eg. "Length DATA31" is cumulative, as is the "WSA allocation size" field in the compile unit prolog. These incorrect sizes also result in incorrect allocation of these areas at run-time.
Local fix
Compile one compile unit at a time
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.1 compiling * * programs in batch mode. * **************************************************************** * PROBLEM DESCRIPTION: The field giving the Length of DATA31 * * in PPA4 is cumulative between * * programs. * **************************************************************** * RECOMMENDATION: Apply provided PTF. * **************************************************************** The field giving the Length of DATA31 in PPA4 was not being reset between batch compiles.
Problem conclusion
Compiler was updated to reset the value for each compile.
Temporary fix
Comments
APAR Information
APAR number
PH02863
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-09-14
Closed date
2018-10-11
Last modified date
2019-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCCBE IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYZQDRV IGYZQENU IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R610 PSY UI59050
UP18/10/19 P F810
R611 PSY UI59051
UP18/10/20 P F810
R612 PSY UI59052
UP18/10/20 P F810
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023