A fix is available
APAR status
Closed as new function.
Error description
Add run-time support for NUMVAL-F, TEST-NUMVAL, TEST-NUMVAL-C, TEST-NUMVAL-F, HEX-TO-CHAR and BIT-TO-CHAR intrinsic functions
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL V6.2 who would * * like to use new intrinsic functions * * NUMVAL-F, TEST-NUMVAL, TEST-NUMVAL-C, * * TEST-NUMVAL-F, HEX-TO-CHAR and BIT-TO-CHAR. * **************************************************************** * PROBLEM DESCRIPTION: New Function: Customers need the * * ability to process floating point * * numbers with exponent fields using an * * intrinsic function the same way fixed * * point numbers are processed using the * * NUMVAL intrinsic function. Customers * * need the ability to validate inputs to * * intrinsic functions NUMVAL and * * NUMVAL-C before processing is done. * * Customers need the ability to process * * HEX and BINARY inputs into * * alphanumeric data items in COBOL. This * * APAR provides support for intrinsic * * functions NUMVAL-F, TEST-NUMVAL, TEST- * * NUMVAL-C, TEST-NUMVAL-F, HEX-TO-CHAR * * and BIT-TO-CHAR for processing * * floating point numbers with exponent * * fields, validating input to intrinsic * * functions NUMVAL, NUMVAL-C and * * NUMVAL-F and processing HEX and BINARY * * inputs into alphanumeric data items in * * COBOL. * **************************************************************** * RECOMMENDATION: Apply the provided PTF to use the new * * intrinsic functions NUMVAL-F, TEST-NUMVAL, * * TEST-NUMVAL-C, TEST-NUMVAL-F, HEX-TO-CHAR * * and BIT-TO-CHAR. * **************************************************************** Customers currently don't have a way to to process floating point numbers with exponent fields using an intrinsic function the same way fixed point numbers are processed using the NUMVAL intrinsic function, customers find that they need to create their own user COBOL libraries if they want to validate inputs to intrinsic functions NUMVAL and NUMVAL-C before processing is done and customers don't have a way to process HEX and BINARY inputs into alphanumeric data items in COBOL. This APAR provides support for intrinsic functions NUMVAL-F, TEST-NUMVAL, TEST-NUMVAL-C, TEST-NUMVAL-F, HEX-TO-CHAR and BIT- TO-CHAR for processing floating point numbers with exponent fields, validating inputs to intrinsic functions NUMVAL, NUMVAL-C and NUMVAL-F and processing HEX and BINARY inputs into alphanumeric data items in COBOL. FIXCAT keyword: COB0501T/K COB0502T/K COB0601T/K COB0602T/K
Problem conclusion
Temporary fix
Comments
The runtime was changed to add support for processing floating point numbers with exponent fields with intrinsic function NUMVAL-F, validating inputs to intrinsic functions NUMVAL, NUMVAL-C and NUMVAL-F with intrinsic functions TEST-NUMVAL, TEST-NUMVAL-C and TEST-NUMVAL-F and processing HEX and BINARY inputs into alphanumeric data items in COBOL with intrinsic functions HEX-TO-CHAR and BIT-TO-CHAR.
APAR Information
APAR number
PH02800
Reported component name
LE ENT COBOL LI
Reported component ID
568819812
Reported release
7B0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-09-13
Closed date
2018-09-20
Last modified date
2018-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI58603 UI58604
Modules/Macros
IGZBALCT IGZCEV4 IGZCMGEN IGZCMGJA IGZCMGUE IGZEDCCT IGZIBMCT IGZIGZCT IGZLLIBV IGZXAPI IGZXCDA IGZXD24 IGZXDMR IGZXFBIN IGZXFHEX IGZXLPIO IGZXLPKA IGZXLPKB IGZXLPKC IGZXLPKD IGZXLPKE IGZXLPKF IGZXLPKG IGZXNMVF IGZXNVFQ IGZXPK2 IGZXTNMV IGZXTNVC IGZXTNVF IGZXUNFQ IGZXUNVF
Fix information
Fixed component name
LE ENT COBOL LI
Fixed component ID
568819812
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCVR7X","label":"Runtime"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020