IBM Support

PH02404: HPIC SETS INCORRECT CONTROL DATA IN THE INTERNAL CONTROL BLOCK WHEN ALL TARGET DATABASES ARE SHISAM AND "STACK=*" IS USED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HPIC sets incorrect control data in the internal control block
    when all target databases are SHISAM and "STACK=*" is used
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The parallel image copy process of IMS  *
    *                      HP Image Copy terminates with ABEND     *
    *                      U3933 ( ABENDU3933 ) when more than one *
    *                      SHISAM database whose maximum segment   *
    *                      length is same are processed with       *
    *                      STACK=*.                                *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    The parallel image copy process of IMS HP Image Copy terminates
    with ABEND U3933  ( ABENDU3933 ) when more than one SHISAM
    database whose maximum segment length is same are processed with
    STACK=*.
    
    IMS HP Image Copy sets the maximum segment length of SHISAM
    database in the incorrect field of its internal control block.
    
    When the requested process is the parallel with STACK=*, IMS HP
    Image copy mishandles the subtask scheduling for parallel
    process due to the incorrect internal control block.
    
    As a result, IMS HP Image Copy terminates with ABEND U3933.
    

Problem conclusion

  • IMS HP Image Copy has added a new field for SHISAM maximum
    segment length in the internal control block and has set its
    maximum segment length in the new field.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH02404

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-09-06

  • Closed date

    2018-09-25

  • Last modified date

    2018-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI58703

Modules/Macros

  • FABJDBD2 FABJDBD3 FABJDBD4 FABJDBD5 FABJDBD9 FABJDBDA FABJDBDB
    FABJRFC2 FABJRFC3 FABJRFC4 FABJRFC5 FABJRFC9 FABJRFCA FABJRFCB
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI58703

       UP18/09/27 P F809

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.