Error description

  • If the customer has Recovery Solution Pack registered, RECOVERY
    sensor and evaluation jobs are performed automatically. However
    the customer would like to run only REORG sensor and evaluation
    jobs.
    We will provide new feature to disable RECOVERY automation.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the Autonomics Director.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: If the customer has Recovery            *
    *                      Solution Pack registered,               *
    *                      RECOVERY sensor and evaluation          *
    *                      are performed automatically.            *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    If the customer has Recovery Solution Pack registered, RECOVERY
    sensor and evaluation jobs are performed automatically.
    However the customer would like to run only REORG sensor and
    evaluation jobs.
    

Problem conclusion

  • The Autonomics Director provides new parameter.
    If user specifies RECOVERY=DISABLE, recovery sensor and
    evaluation will not be performed automatically.
    
    1. ADD 'RECOVERY=DISABLE' parameter to IAVPCOM member in your
    PROCLIB like as below.
    
    XCFGROUP=adm00,
    ITKBGROUP=srvrname,
    WLMRINT=0,
    RACFAPPL=adracf,
    RECOVERY=DISABLE,
    JCLLIB=yourhlq.JCLLIB
    
    2. Start the Autonomics Director server.
    The following job log messages indicate that recovery sensor
    and evaluation will not be performed automatically.
    
    IAV0704I - RECOVERY SENSOR AND EVALUATION AUTOMATION IS DISABLED
    
    New parameter is:
    RECOVERY
    (Optional) Specify the Recovery sensor and evaluation
    automation enable and disable.
    You can set this parameter to ENABLE and DISABLE. The default
    value is ENABLE.
    If you set DISABLE, Recovery sensor and evaluation will not be
    performed automatically.
    
    New Message is:
    IAV0704I RECOVERY SENSOR AND EVALUATION AUTOMATION IS DISABLED
    Explanation: The Autonomics Director environment has IMS
    Recovery Solution Pack.
    However Recovery sensor and evaluation jobs will not be
    performed automatically.
    System action: Processing continues.
    User response: None.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH01825

  • Reported component name

    TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    160

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2018-08-16

  • Closed date

    2018-08-28

  • Last modified date

    2019-05-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI58083

Modules/Macros

  • IAVD0ENU IAVDOCDR IAVDPLP0 IAVDSTIM
    

Fix information

  • Fixed component name

    TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R160 PSY UI58083

       UP18/08/31 P F808