Fixes are available
APAR status
Closed as program error.
Error description
When accessing test data in a stub, the Lookup Test Data step can fail with the following error: [RunTests/instance5 (6)]: [06/21/2018, 12:59:58.072 PM] [Error] Instance 6: Lookup Test Data: Search "XXXXXX (Lookup)" for "%%XXXXXX%%" in "XXXXXX" and for "%%XXXXXX%%" in "XXXXXX" Null Pointer Exception: null [RunTests/instance5 (6)]: com.ghc.ghTester.runtime.actions.TestDataLookupAction.X_performL ookup(TestDataLookupAction.java:281) [RunTests/instance5 (6)]: com.ghc.ghTester.runtime.actions.TestDataLookupAction.execute(Te stDataLookupAction.java:153) [RunTests/instance5 (6)]: com.ghc.ghTester.runtime.actions.GHTesterAction.execute(GHTester Action.java:107) WORKAROUND: Deploy the stub with 1 Worker.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Rational Integration Tester with test actions that * * lookup test data * **************************************************************** * PROBLEM DESCRIPTION: * * In some circumstances, a stub using a Lookup Test Data * * action could have intermittent failures. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in 9.2.1
Temporary fix
Comments
APAR Information
APAR number
PH00532
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-07-16
Closed date
2018-10-03
Last modified date
2018-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSN
UP
R920 PSN
UP
R921 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"920","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: