Error description

  • OMEGAMON DATA PROVIDER 2024 Q1 MAINTENANCE
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All OMEGAMON Data Provider users.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: OMEGAMON DATA PROVIDER 2024 Q1          *
    *                      MAINTENANCE                             *
    ****************************************************************
    This APAR includes new features and minor fixes.
    
    New features
    ------------
    
    OMEGAMON Data Broker:
    
    -  New version of protocol between OMEGAMON Data Broker and
       OMEGAMON Data Connect.
    
       Version 2 of this protocol improves performance and
       reliability.
    
    -  Store parameters for queue capacity and cells are now
       optional.
    
       Previously, these parameters were required.
    
       Now, these parameters are optional, with default values.
       You can omit (remove) these parameters from your
       configuration member.
    
    -  Reusable sink parameters.
    
       You can now define reusable sink parameters separately from
       forwarders. Multiple forwarders can refer to the same set of
       reusable sink parameters. Reusable sink parameters make it
       easier to forward data from different sources to the same
       sink (the same instance of OMEGAMON Data Connect).
    
    -  Improved validation of configuration parameters.
    
       OMEGAMON Data Broker validates more configuration
       parameters at startup.
    
    OMEGAMON Data Connect:
    
    -  Support for new version of OMEGAMON Data Broker forwarder
       protocol.
    
       OMEGAMON Data Connect supports the new version 2 of the
       OMEGAMON Data Broker forwarder protocol.
    
    -  Improved validation of configuration parameters.
    
       Previously, OMEGAMON Data Connect silently ignored unknown
       parameters in the configuration file.
    
       Now, if the configuration file contains an unknown parameter,
       OMEGAMON Data Connect fails at startup.
    
       If your configuration file contains errors that were
       previously silently ignored, this is a breaking change.
       You must edit the configuration file and fix the issue.
    
    -  Configuration validator.
    
       The OMEGAMON Data Provider configuration validator is a new
       command-line tool that you can use to validate the two
       YAML-format OMEGAMON Data Provider configuration files:
       -  The OMEGAMON Data Connect configuration file
       -  If you are using OMEGAMON monitoring agents as a data
          source: the OMEGAMON Data Provider collection
          configuration member, RKANPARU(KAYOPEN)
    
    -  Sample shell script z/OS UNIX file now encoded using
       EBCDIC code page 1047
    
       You no longer need to activate automatic text conversion to
       run the sample shell script to start OMEGAMON Data Connect on
       z/OS UNIX.
    

Problem conclusion

Temporary fix

Comments

  • User Action:
    New users installing OMEGAMON Data Provider for the first time:
    1. SMP/E Apply the fix.
    
    Existing users must follow these upgrade steps:
    1. If you have modified files in the OMEGAMON Data Connect
       directory (DDDEF name TKAYHFS), back up the modified files
       to another location.
       This PTF replaces all files in the OMEGAMON Data Connect
       directory.
    2. SMP/E Apply the fix.
    3. Perform the upgrade steps described in the OMEGAMON
       Data Provider product documentation (https://www.ibm.com/
       docs/SSFHX8_5.6.0/OMDP/source/kay-upgrade.html).
    

APAR Information

  • APAR number

    OA66223

  • Reported component name

    OMEGA DATA PROV

  • Reported component ID

    5698B6605

  • Reported release

    110

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-03-06

  • Closed date

    2024-05-07

  • Last modified date

    2024-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ95209

Modules/Macros

  • KAY11PAX KAY11ZIP KAY1BDP  KAY1LDP  KAY1ODP  KAY4BDP  KAY4LDP
    KAY4ODP  KAYB0001 KAYBNETL KAYOPEN  KAYSIP00 KAYSIS01 KAYSISDL
    

Fix information

  • Fixed component name

    OMEGA DATA PROV

  • Fixed component ID

    5698B6605

Applicable component levels

  • R110 PSY UJ95209

       UP24/05/23 P F405

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.