IBM Support

OA65454: WHEN USING SMF_023 DATASTREAM, WE ONLY SEE THE STATISTICS FOR THE FIRST LOGSTREAM.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • When using SMF_023 datastream, we only see the statistics for
    the first logstream.
    
    ANALYSIS:
    We need define the section SMF_LGS as a repeated section so that
    the SMF
    log stream statistics can be collected for ALL SMF logstreams.
    Simply adding REPEATED to the section will cause the SMF
    statistics section (SMF_STAT)
    to be sent multiple times per interval.
    
    To resolve, we  introduce two new data streams. One data stream
    is
    SMF_023_V2 which is for the main record. One record is produced
    per SMF
    interval. The other data stream SMF_023_LGS is for the repeated
    section
    SMF_LGS. Multiple records (one per logstream) are produced per
    SMF interval.
    
    The behavior of the existing data stream SMF_023 remains
    unchanged.
    
    
    ADDITIONAL SYMPTOMS:
    When using SMF23 datastream, we only see the statistics for the
    first logstream.
    

Local fix

  • BYPASS/CIRCUMVENTION:
    Temp fix is available via suppport
    

Problem summary

Problem conclusion

Temporary fix

Comments

  • The fix has been included in the CDP 24 1Q CD, the APAR number
    is OA65670, the PTF number is UJ94825.
    

APAR Information

  • APAR number

    OA65454

  • Reported component name

    CDP BASE

  • Reported component ID

    5698ABJ00

  • Reported release

    510

  • Status

    CLOSED DUB

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-08-31

  • Closed date

    2024-04-12

  • Last modified date

    2024-04-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"510"}]

Document Information

Modified date:
12 April 2024