Error description
CDP 2023 2Q Continous Delivery: Main Feature: Refer to the link to get more details about the new features below: https://www.ibm.com/docs/en/z-logdata-analytics/ 5.1.0?topic=whats-new-in-version-510 - Support sending data to Kafka via SASL/Kerberos authorities. - Separation of z/OS SYSLOG Message ID and Message Text in Humio. - Add "Health Check" function for Data Streamer. - Serviceability improvement on CICS CMF data collection. - Support MQ 9.3.0. - Support IMS 15.3.0. - Enhance the mechanism to collect SMF records from exit and in-memory resource. - Refresh Policy without recycling Data Collector. - Support Joblog, VSAM, USS log, NetView WasHpel and Sequential Dataset in Data Collector. - Support SMF type 1154_97. - Add a summary file after saving policy. - Enhance DC configuration on UI. - Merge APAR fix until OA64228,OA64229 & OA63923 into CDP v510. Key Defects Fixed: - Duplicate record read produced for data streams with data aggregation when reading SMF from kafka. - Data Streamer reports 'java.lang.NullPointerException' exception when reading OMEGAMON data. - Can not collect data from sequential data set(not GDG). - IKJ56231I & IKJ56247I reported when collecting generation data group. - HBOCOL job fails with HBO0049I. - SDE failed because of data overflow when running AIHA2DUN. - HBO6064E reported in data streamer when use dynamic trace.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All ZAA (IBM Z Anomaly Analytics with * * Watson) and ZLDA (IBM Z Operational Log and * * Data Analytics) V5.1 users of CDP (Common * * Data Provider) * **************************************************************** * PROBLEM DESCRIPTION: CDP 2023 2Q Continous Delivery: * * * * Main Feature: * * Refer to the link to get more details * * about the new features below: * * https://www.ibm.com/docs/en/ * * z-logdata-analytics/ * * 5.1.0?topic=whats-new-in-version-510 * * - Support sending data to Kafka via * * SASL/Kerberos authorities. * * - Separation of z/OS SYSLOG Message ID * * and Message Text in Humio. * * - Add "Health Check" function for Data * * Streamer. * * - Serviceability improvement on CICS * * CMF data collection. * * - Support MQ 9.3.0. * * - Support IMS 15.3.0. * * - Enhance the mechanism to collect SMF * * records from exit and in-memory * * resource. * * - Refresh Policy without recycling Data * * Collector. * * - Support Joblog, VSAM, USS log, * * NetView WasHpel and Sequential Dataset * * in Data Collector. * * - Support SMF type 1154_97. * * - Add a summary file after saving * * policy. * * - Enhance DC configuration on UI. * * - Merge APAR fix until OA64228,OA64229 * * & OA63923 into CDP v510. * * Key Defects Fixed: * * - Duplicate record read produced for * * data streams with data aggregation when * * reading SMF from kafka. * * - Data Streamer reports * * 'java.lang.NullPointerException' * * exception when reading OMEGAMON data. * * - Can not collect data from sequential * * data set(not GDG). * * - IKJ56231I & IKJ56247I reported when * * collecting generation data group. * * - HBOCOL job fails with HBO0049I. * * - SDE failed because of data overflow * * when running AIHA2DUN. * * - HBO6064E reported in data streamer * * when use dynamic trace. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** - Duplicate record read produced for data streams with data aggregation when reading SMF from kafka. In some cases when reading SMF from kafka, SDE will read the data which has already been aggregated which will cause duplicate data reported. - Data Streamer reports 'java.lang.NullPointerException' exception when reading OMEGAMON data. Some entries defined in data stream dictionary will not be filled with value when reading OMEGAMON data which will cause NullPointerException. - Can not collect data from sequential data set(not GDG). The file position has not been set correctly if sequential data set is created after Log Forwarder starts which will cause no data collected. - IKJ56231I & IKJ56247I reported when collecting generation data group. If there's a large amount of data in kafka when SDE starts, the msgList will increase faster than SDE consumes which causes OutOfMemoryError of SDE. - HBOCOL job fails with HBO0049I. SDE parses a variable which is not previously set which will cause HBO0049I. - SDE failed because of data overflow when running AIHA2DUNIn ZAA, some fields are defined as SUM which will cause the value can be greater than 2147483647 which is the largest number for a Fixed(31) field in some cases, then there will be data overflow occur. - HBO6064E reported in data streamer when use dynamic trace. The gather class does not have its own logger which will cause HBO6046E when modifying the log level dynamically.
Problem conclusion
CDP is updated to add the new features and fix the key defects above.
Temporary fix
Comments
APAR Information
APAR number
OA64556
Reported component name
CDP BASE
Reported component ID
5698ABJ00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2023-03-19
Closed date
2023-05-11
Last modified date
2023-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ92789
Modules/Macros
HBO2CCMF HBO2CD41 HBO2CD42 HBO2CD51 HBO2CD52 HBO2CD53 HBO2CD54 HBO2CD55 HBO2CD56 HBO2CD61 HBO2CDIC HBO2CIST HBO2COMP HBO2S030 HBO2S042 HBO2S070 HBO2S078 HBO2S104 HBO2S113 HBO2S30A HBO2S30O HBO2S42V HBO2S701 HBO2S702 HBO2TS77 HBO3CIST HBO3S701 HBOA2DUN HBOAKCUN HBOAKDUN HBOAKZUN HBOAPMUN HBOCCORN HBOCCORY HBOCCSV HBOCDEDC HBOCDEDE HBOCDEDS HBOCDELF HBOCDEUI HBOCFGA HBOCFGT HBOCHGP HBOCMAIN HBODCBAT HBODCCOL HBODEPS HBODS001 HBODSDBG HBODSPCE HBODSPRO HBODSRAW HBOFLGX0 HBOGDSDL HBOGLMSG HBOGTDBG HBOIMS HBOJBCO2 HBOJBCOL HBOJBDC2 HBOJBDCO HBOJBIM2 HBOJBIMS HBOJCOLL HBOJIMS HBOLDCOL HBOLFBCH HBOLFPCE HBOLLSMF HBOMDBG HBONETV HBOPASDI HBOPBLVL HBOPCDBI HBOPCGAA HBOPCGB1 HBOPCGB2 HBOPCGCM HBOPCGCW HBOPCGGC HBOPCGGF HBOPCGGP HBOPCGGX HBOPCGJA HBOPCGJC HBOPCGJE HBOPCGLO HBOPCGLW HBOPCGNN HBOPCGNO HBOPCGO1 HBOPCGO2 HBOPCGO3 HBOPCGO4 HBOPCGP1 HBOPCGP2 HBOPCGPA HBOPCGPC HBOPCGPF HBOPCGPN HBOPCGPP HBOPCGRC HBOPCGSF HBOPCGSM HBOPCGSW HBOPCGWD HBOPCGXC HBOPCGXF HBOPCGXI HBOPCGXS HBOPCGXT HBOPCGXV HBOPCGZA HBOPCGZC HBOPCGZG HBOPCGZM HBOPCGZP HBOPCGZS HBOPCGZZ HBOPCIBM HBOPCICP HBOPCMAA HBOPCMCR HBOPCMEV HBOPCMFP HBOPCMRN HBOPCMSC HBOPCMSP HBOPCMST HBOPCMSU HBOPCMSV HBOPCMZZ HBOPCOAS HBOPCOBF HBOPCOBI HBOPCOBU HBOPCOCF HBOPCOCR HBOPCOCS HBOPCODB HBOPCODI HBOPCOHA HBOPCOIT HBOPCOLL HBOPCOLX HBOPCOME HBOPCOMM HBOPCOMR HBOPCOOT HBOPCORE HBOPCORX HBOPCOSF HBOPCOST HBOPCOUR HBOPCOUT HBOPCPRE HBOPCSVD HBOPCXAA HBOPCXCA HBOPCXCC HBOPCXCT HBOPCXFC HBOPCXFI HBOPCXIC HBOPCXID HBOPCXLD HBOPCXLO HBOPCXNN HBOPCXNU HBOPCXO1 HBOPCXO2 HBOPCXO3 HBOPCXO4 HBOPCXPX HBOPCXSE HBOPCXUS HBOPCXVA HBOPCXVR HBOPDBRC HBOPDE HBOPDELO HBOPDERE HBOPDERP HBOPDETA HBOPDETP HBOPDEUP HBOPDICA HBOPDICC HBOPDICD HBOPDICF HBOPDICI HBOPDICR HBOPDICS HBOPFRFA HBOPFRFL HBOPFRFM HBOPFRFN HBOPFRFT HBOPFRLX HBOPFRSA HBOPFRSL HBOPFRSN HBOPFRSS HBOPIFAQ HBOPIMID HBOPIMS HBOPIMSD HBOPIMSN HBOPIO HBOPIO31 HBOPLIPR HBOPLODT HBOPLOEX HBOPLOG HBOPLOOI HBOPLOOK HBOPLOOU HBOPLOPE HBOPLOPF HBOPLOPR HBOPLOST HBOPLSMC HBOPLSPR HBOPMG HBOPMG00 HBOPMG01 HBOPMG02 HBOPMG03 HBOPMG04 HBOPMG05 HBOPMG21 HBOPMG29 HBOPMG50 HBOPMG52 HBOPMG80 HBOPMG81 HBOPMG82 HBOPNCCI HBOPNCCR HBOPNCCS HBOPNCDF HBOPNCFD HBOPOLDS HBOPPACO HBOPPAER
Fix information
Fixed component name
CDP BASE
Fixed component ID
5698ABJ00
Applicable component levels
R510 PSY UJ92789