IBM Support

OA63923: CDP UPDATE FOR SDE IN IMS COLLECTOR.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CDP update for SDE in IMS collector with these issues fixed:
    - SDE Abend 0C4 in module HBOPOLDS.
    - SDE abend with message CSV002I.
    - HBO0386I reported with 'Return Code:  0000000C' and 'Reason
    Code: C9000003'
    - SDE will pause the IMS reorg process for more than 10 minutes.
    - High CPU of HBOIMS.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM Common Data Provider for z  *
    *                 Systems v2.1.                                *
    ****************************************************************
    * PROBLEM DESCRIPTION: CDP update for SDE in IMS collector     *
    *                      with these issues fixed:                *
    *                      - SDE Abend 0C4 in module HBOPOLDS.     *
    *                      - SDE abend with message CSV002I.       *
    *                      - HBO0386I reported with 'Return Code:  *
    *                      0000000C' and 'Reason Code: C9000003'   *
    *                      - SDE will pause the IMS reorg process  *
    *                      for more than 10 minutes.               *
    *                      - High CPU of HBOIMS.                   *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    - SDE Abend 0C4 in module HBOPOLDS.
    In some cases, the OLDS_ENTRY is not set correctly by CDP which
    will cause pointing to an invalid address and then abend 0C4.
    
    - SDE abend with message CSV002I.
    The IMS collector needs to be reworked with updated usage of
    DBRC API to avoid CSV002I and abend.
    
    - HBO0386I reported with 'Return Code: 0000000C' and 'Reason
    Code: C9000003'
    During IMS reorg process, sometimes the RECON1 used by DBRC API
    request will become invalid. This is due to the requirement of
    the DBRC API, and it will prevent the DBRC API from completing
    as expected. This causes SDE to report HBO0386I with return
    code and reason code above. SDE is updated to check the RECON
    status and updated the RECON1 used by DBRC API before issuing it
    to prevent this issue.
    
    - SDE will pause the IMS reorg process for more than 10 minutes.
    During reorg process, SDE will not notify if the RECON dataset
    which is being used needs to be switched until next discovery
    which will pause the IMS reorg process.
    
    - High CPU of HBOIMS.
    There is a potential looping in dispatch process of I/O program
    when collecting IMS log which will cause high CPU usage.
    

Problem conclusion

  • CDP v2.1 is updated to rework the IMS collector with these
    issues fixed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA63923

  • Reported component name

    CDP BASE

  • Reported component ID

    5698ABJ00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-10-13

  • Closed date

    2023-02-22

  • Last modified date

    2023-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ92266

Modules/Macros

  • HBO2CCMF HBO2CD41 HBO2CD42 HBO2CD51 HBO2CD52 HBO2CD53 HBO2CD54
    HBO2CD55 HBO2CD56 HBO2CD61 HBO2CDIC HBO2CIST HBO2COMP HBO2OMEG
    HBO2S030 HBO2S042 HBO2S070 HBO2S078 HBO2S104 HBO2S113 HBO2S30A
    HBO2S30O HBO2S42V HBO2S701 HBO2S702 HBO2TS77 HBO3CIST HBO4CICS
    HBOA2DUN HBOAKCUN HBOAKDUN HBOAKZUN HBOAPMUN HBODSDBG HBODSPCE
    HBOFLGX0 HBOGTDBG HBOIMS   HBOJBCO2 HBOJBCOL HBOJBDC2 HBOJBDCO
    HBOJBIM2 HBOJBIMS HBOJCOLL HBOJIMS  HBOPASDI HBOPBLVL HBOPCDBI
    HBOPCGAA HBOPCGB1 HBOPCGB2 HBOPCGCM HBOPCGCW HBOPCGGC HBOPCGGF
    HBOPCGGP HBOPCGGX HBOPCGJA HBOPCGJC HBOPCGJE HBOPCGLO HBOPCGLW
    HBOPCGNN HBOPCGNO HBOPCGO1 HBOPCGO2 HBOPCGO3 HBOPCGO4 HBOPCGP1
    HBOPCGP2 HBOPCGPA HBOPCGPC HBOPCGPF HBOPCGPN HBOPCGPP HBOPCGRC
    HBOPCGSF HBOPCGSM HBOPCGSW HBOPCGWD HBOPCGXC HBOPCGXF HBOPCGXI
    HBOPCGXS HBOPCGXT HBOPCGXV HBOPCGZA HBOPCGZC HBOPCGZG HBOPCGZM
    HBOPCGZP HBOPCGZS HBOPCGZZ HBOPCIBM HBOPCICP HBOPCMAA HBOPCMCR
    HBOPCMEV HBOPCMFP HBOPCMRN HBOPCMSC HBOPCMSP HBOPCMST HBOPCMSU
    HBOPCMSV HBOPCMZZ HBOPCOAS HBOPCOB2 HBOPCOBI HBOPCOBU HBOPCOCF
    HBOPCOCR HBOPCOCS HBOPCODB HBOPCODI HBOPCOHA HBOPCOIT HBOPCOLL
    HBOPCOLX HBOPCOME HBOPCOMM HBOPCOMR HBOPCOOT HBOPCORE HBOPCORX
    HBOPCOSF HBOPCOST HBOPCOUR HBOPCOUT HBOPCPRE HBOPCSVD HBOPCXAA
    HBOPCXCA HBOPCXCC HBOPCXCT HBOPCXFC HBOPCXFI HBOPCXIC HBOPCXID
    HBOPCXLD HBOPCXLO HBOPCXNN HBOPCXNU HBOPCXO1 HBOPCXO2 HBOPCXO3
    HBOPCXO4 HBOPCXPX HBOPCXSE HBOPCXUS HBOPCXVA HBOPCXVR HBOPDBRC
    HBOPDE   HBOPDELO HBOPDERE HBOPDERP HBOPDETA HBOPDETP HBOPDEUP
    HBOPDICA HBOPDICC HBOPDICD HBOPDICF HBOPDICI HBOPDICR HBOPDICS
    HBOPFRFA HBOPFRFL HBOPFRFM HBOPFRFN HBOPFRFT HBOPFRLX HBOPFRSA
    HBOPFRSL HBOPFRSN HBOPFRSS HBOPIFAQ HBOPIMS  HBOPIMSD HBOPIO
    HBOPIO31 HBOPLIIT HBOPLIIX HBOPLILI HBOPLIOB HBOPLIPR HBOPLIRE
    HBOPLIST HBOPLODT HBOPLOEX HBOPLOG  HBOPLOOI HBOPLOOK HBOPLOOU
    HBOPLOPE HBOPLOPF HBOPLOPR HBOPLOST HBOPLSMC HBOPLSPR HBOPMG
    HBOPMG00 HBOPMG01 HBOPMG02 HBOPMG03 HBOPMG04 HBOPMG05 HBOPMG21
    HBOPMG29 HBOPMG50 HBOPMG52 HBOPMG80 HBOPMG81 HBOPMG82 HBOPNCCI
    HBOPNCCR HBOPNCCS HBOPNCDF HBOPNCFD HBOPOLDS HBOPPACO HBOPPAER
    HBOPPAEX HBOPPAFI HBOPPARS HBOPPCOL HBOPPHFS HBOPPVER HBOPRCDP
    HBOPRECB HBOPRECO HBOPRECS HBOPRECX HBOPREEX HBOPREIX HBOPRENX
    HBOPRPRO HBOPRPRS HBOPSCAN HBOPSCRT HBOPSECF HBOPSECN HBOPSECT
    

Fix information

  • Fixed component name

    CDP BASE

  • Fixed component ID

    5698ABJ00

Applicable component levels

  • R210 PSY UJ92266

       UP23/02/24 P F302

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"210"}]