IBM Support

OA63568: RMM LEAVES WHILECATALOG UNTILEXPIRED ATTRIBUTE OFF FOR THE FIRST VOLUME IN A MULTIVOLUME SET UNDER RM(EXPDT) RETAINBY(VOLUME)

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Under the EXPDT Retention Method with WHILECATALOG(UNTILEXPIRED)
    and RETAINBY(VOLUME), there is a scenario where RMM does not
    correctly leave the WHILECATALOG(UNTILEXPIRED) attribute in
    place for the first volume in a multivolume set. In the reported
    case, the first volume contains a dataset entirely, the second
    dataset spans the first and second volume, and the third dataset
    spans the second and third volume in the set. When the third
    dataset extends to the third volume in the set, the WC(UX)
    attribute is properly turned off on volume two but erroneously
    turned off on volume one where the third dataset does not
    reside. Then when this third dataset is finished being written
    and catalog calls RMM to indicate CATALOG=YES, the WC(UX)
    attribute is turned on for volumes two and three, but left off
    for volume one. This can lead to volume one being retained by
    expiration date alone instead of properly considering the
    catalog entry of the datasets on the volume with OrUncatlg.
    Under RETAINBY(SET) all volumes are consistently retained
    properly as the expiration date and attributes of all volumes in
    a set are kept the same.
    
    DSN1 VOL1 has WC(UX)
    DSN2 VOL1,VOL2 have WC(UX)
    DSN3 VOL2,VOL3 have WC(UX)
    
    VOL1 does NOT have OrUncatlg
    VOL2 does have OrUncatlg
    VOL3 does have OrUncatlg
    
    The results of this error could be that volumes are retained
    longer than intended, which could lead to out of scratch or out
    of cache conditions(VTS).
    

Local fix

  • BYPASS/CIRCUMVENTION:
    Use RETAINBY(SET) instead of RETAINBY(VOLUME) in EDGRMMxx,
    Volume Set Management Level in MC class definition, and/or
    RETAINBY value in DEFAULT TABLE entries as appropriate.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * ALL DFSMSrmm clients using the RMM EXPDT retention method    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In a Multivolume set retained by volume under EXPDT          *
    * retention method                                             *
    * the WHILECATALOG(UNTILEXPIRED) attribute is not set          *
    * correctly for                                                *
    * some of the volumes in the chain. This can cause the         *
    * impacted volumes                                             *
    * to be retained longer than required.                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • EDGMFIO is updated to fix the missing WHILECATALOG(UNTILEXPIRED)
     flag for Initial volumes.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    OA63568

  • Reported component name

    DFSMSRMM

  • Reported component ID

    5695DF186

  • Reported release

    240

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-07-25

  • Closed date

    2023-09-07

  • Last modified date

    2023-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ93653 UJ93663 UJ93664

Modules/Macros

  • EDGMFIO
    

Fix information

  • Fixed component name

    DFSMSRMM

  • Fixed component ID

    5695DF186

Applicable component levels

  • R250 PSY UJ93664

       UP23/10/04 P F310 ¢

  • R240 PSY UJ93663

       UP23/10/04 P F310 ¢

  • R310 PSY UJ93653

       UP23/10/04 P F310 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"240"}]

Document Information

Modified date: