IBM Support

OA62782: ABEND U0060 WHEN USING FILE BASED TASK HISTORY AND HAVE DETAIL COLLECTION FOR MQ BEING WRITTEN TO ONDV 22/01/31 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When the MQ file detail records are compressed it is not
    possible to decompress then successfully.
    

Local fix

  • No local fix.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All OMEGAMON for CICS on z/OS users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Following UJ06731 task history may      *
    *                      abend U0060 if file level collection    *
    *                      for MQ is being written to ONDV.        *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    UJ06731 caused MQ task history records to be compressed
    incorrectly.
    

Problem conclusion

  • Task history records for MQ are now processed correctly.
    Application Trace has been expanded to store task trace data
    above the 2GB Bar. This data can now be up to 320K per task.
    Application Trace filters can now be defined in the Global Data
    area. These can be defined to repeat either hourly, daily or
    weekly on a specific day.
    The ability to purge Intra partition Transient data queues has
    been added to the Enhanced 3270 UI.
    OMEGAMON for CICS task history transaction start times and end
    times are now rounded to the thousandths of a second.
    
    The Self-Describing Agent deliverables included
    in this APAR are equivalent to the application
    support files shipped in the associated Fix Pack:
    
    5.5.0-TIV-KC5-FP0007.tar.gz
    5.5.0-TIV-KC5-FP0007.zip
    
    After installing this PTF, you must reload the RTE
    where an OMEGAMON for CICS on z/OS agent is running
    and then restart the agent.
    
    If you are NOT using the Self-Defining Agent (SDA) feature,
    this PTF must be installed in conjunction with fix pack
    5.5.0-TIV-KC5-FP0007 which must be applied to the TEPS
    environment and, if the hub TEMS is running on a non-z/OS
    platform it must be applied to the hub TEMS.
    However, if you are using SDA, this is not necessary.
    
    The SDA feature does not update the application support used
    by the TEP Desktop Client. To update the TEP Desktop Client's
    application support to the level delivered by this
    PTF, you must also install fix pack 5.5.0-TIV-KC5-FP0007.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA62782

  • Reported component name

    OMEG XE CICS Z/

  • Reported component ID

    5698A5800

  • Reported release

    550

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-01-31

  • Closed date

    2022-02-07

  • Last modified date

    2022-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • KC256DG1 KC5AFF00 KC5AFSEA KC5AFSFA KC5AFSGA KC5AFSHA KC5AFSIA
    KC5AFSJA KC5AFSKA KC5AFSLA KC5AFSMA KC5AGENT KC5ATF@S KC5CAD@S
    KC5DCC@S KC5NOD00 KC5ODV@S KC5OND00 KC5OTR@S KC5PDICT KC5RLU00
    KC5STOE0 KC5STOF0 KC5STOG0 KC5STOH0 KC5STOI0 KC5STOJ0 KC5STOK0
    KC5STOL0 KC5STOM0 KC5TAN@S KC5TASEA KC5TASFA KC5TASGA KC5TASHA
    KC5TASIA KC5TASJA KC5TASKA KC5TASLA KC5TASMA KC5TD2@S KC5TR1@S
    KC5TR2@S KC5TR3@S KC5TRD@S KC5TRE@S KC5TRF@S KC5TRP@S KC5TRR@S
    KC5TRS@S KC5TRT@S KC5TRU@S KC5TSM@S KC5TTT@S KC5UOW@S KC5WCR0A
    KCEAGENT KCETML@S KCPATF   KCPATF3  KCPATF4  KCPATF5  KCPATF6
    KCPATR   KCPBAR   KCPCAT   KCPCTXT1 KCPDOC   KCPH0001 KCPH0002
    KCPH0003 KCPH0004 KCPH0005 KCPH0006 KCPH0007 KCPH0008 KCPH0009
    KCPH0010 KCPH0011 KCPH0012 KCPH0013 KCPH0014 KCPH0015 KCPH0016
    KCPH0017 KCPH0018 KCPH0019 KCPH0020 KCPH0021 KCPH0022 KCPH0023
    KCPH0024 KCPH0025 KCPH0026 KCPH0027 KCPH0028 KCPH0029 KCPH0030
    KCPH0031 KCPH0032 KCPH0033 KCPH0034 KCPH0035 KCPH0036 KCPH0037
    KCPH0038 KCPH0039 KCPH0040 KCPH0041 KCPH0042 KCPH0043 KCPH0044
    KCPH0045 KCPH0046 KCPH0047 KCPH0048 KCPH0049 KCPH0050 KCPH0051
    KCPH0052 KCPH0053 KCPH0054 KCPH0055 KCPH0056 KCPH0057 KCPH0058
    KCPH0059 KCPH0060 KCPH0061 KCPH0062 KCPH0063 KCPH0064 KCPH0065
    KCPH0066 KCPH0067 KCPH0068 KCPH0069 KCPH0070 KCPH0071 KCPH0072
    KCPH0073 KCPH0074 KCPH0075 KCPH0076 KCPH0077 KCPH0078 KCPH0079
    KCPH0080 KCPH0081 KCPH0082 KCPH0083 KCPH0084 KCPH0085 KCPH0086
    KCPH0087 KCPH0088 KCPH0089 KCPH0090 KCPH0091 KCPH0092 KCPH0093
    KCPH0094 KCPH0095 KCPH0096 KCPH0097 KCPH0098 KCPH0099 KCPH0100
    KCPH0101 KCPH0102 KCPH0103 KCPH0104 KCPH0105 KCPH0106 KCPH0107
    KCPH0108 KCPH0109 KCPH0110 KCPH0111 KCPH0112 KCPH0113 KCPH0114
    KCPH0115 KCPH0116 KCPH0117 KCPH0118 KCPH0119 KCPH0120 KCPH0121
    KCPH0122 KCPH0123 KCPH0124 KCPH0125 KCPH0126 KCPH0127 KCPH0128
    KCPH0129 KCPH0130 KCPH0131 KCPH0132 KCPH0133 KCPH0134 KCPH0135
    KCPH0136 KCPH0137 KCPH0138 KCPH0139 KCPH0140 KCPH0141 KCPH0142
    KCPH0143 KCPH0144 KCPH0145 KCPH0146 KCPH0147 KCPH0148 KCPH0149
    KCPH0150 KCPINDEX KCPJSTMS KCPJSTPS KCPJSTPW KCPMAP   KCPMSMAN
    KCPPDICT KCPTAHFN KCPTASD  KCPTASHE KCPTASTR KCPTATFF KCPTDQAP
    KCPTDQAX KCPTDQS  KCPTDQSX KCPVER   KCPVRTMS KOCAFF00 KOCAFSEA
    KOCAFSFA KOCAFSGA KOCAFSHA KOCAFSIA KOCAFSJA KOCAFSKA KOCAFSLA
    

Fix information

  • Fixed component name

    OMEG XE CICS Z/

  • Fixed component ID

    5698A5800

Applicable component levels

  • R550 PSY UJ07731

       UP22/02/09 P F202 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLSDR","label":"Tivoli OMEGAMON XE for CICS on z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"550"}]

Document Information

Modified date:
02 March 2022