A fix is available
APAR status
Closed as program error.
Error description
When collecting OPERLOG, the CEE0802C message is issued after the Log Forwarder has been running for a period.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Common Data Provider for z * * Systems v2.1. * **************************************************************** * PROBLEM DESCRIPTION: When collecting OPERLOG, the CEE0802C * * message is issued after the Log * * Forwarder has been running for a * * period. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** The storage check of OPERLOG collection is incorrect, which causes a storage overlay and then CEE0802C is reported.
Problem conclusion
CDP v2.1 is updated to fix this problem.
Temporary fix
Comments
APAR Information
APAR number
OA62504
Reported component name
CDP BASE
Reported component ID
5698ABJ00
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-11-23
Closed date
2022-04-02
Last modified date
2022-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ08145
Modules/Macros
HBOCFPSH HBODSRAW HBOENCSH HBOGDSDL HBOGLMSG HBOLFBCH HBOLFPCE HBOLOGPR HBOMDBG HBOMUESH HBONETV HBOPROC HBORACF HBOSTRSH HBOSYSG HBOTRSTJ HBOUERQ HBOUTJAR HBOZLF64 HBOZLFJ HBOZLFRQ
Fix information
Fixed component name
CDP BASE
Fixed component ID
5698ABJ00
Applicable component levels
R210 PSY UJ08145
UP22/05/03 P F204
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.