A fix is available
APAR status
Closed as program error.
Error description
After upgrading Chrome browser to version 86.0.4240.111 HOD Launcher no longer works as expected.HOD Launcher keeps on getting launched in an infinite loop causing the end user to see the browser popup constantly and hence it requires the user's interaction to close the popup (repeatedly)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Chrome browser with HOD Launcher * **************************************************************** * PROBLEM DESCRIPTION: * * In Chrome browser console HODLauncher.html, error message is * * displayed: * * 1. Not allowed to launch because a user gesture is required * **************************************************************** * RECOMMENDATION: * **************************************************************** With Google Chrome version 86.0.4240.111 and accessing HOD page using HOD Launcher, error message gets displayed in browser console continuously.
Problem conclusion
Code change has been made to fix this issue. Fix included in HOD 12.0.7, HOD 13.0.5, HOD 14.0.3.
Temporary fix
Comments
APAR Information
APAR number
OA60657
Reported component name
HOD MVS
Reported component ID
5733A5900
Reported release
C00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-12-15
Closed date
2021-05-27
Last modified date
2021-05-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HOD
Fix information
Fixed component name
HOD MVS
Fixed component ID
5733A5900
Applicable component levels
RC00 PSY
UP
RD00 PSY
UP
RE00 PSY
UP
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSS9FA","label":"IBM Host On-Demand"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C00"}]
Document Information
Modified date:
30 August 2021