A fix is available
APAR status
Closed as program error.
Error description
an 0C4 occurs in module AGMYIO which causes the IMS message processing region to abend
Local fix
Problem summary
AGMYIO collects information on database calls and stores this information in 64 bit storage. Some of the registers that were being used in 64 bit addressing mode had not been properly initialized and had erroneous data in the high half of the register due to certain system settings.
Problem conclusion
The registers that had been improperly initialized have had their high halves cleared before using them to map storage in 64bit addressing mode. This APAR also addresses a potential problem with running fast path transactions which use databases other than DEDB/MSDB in an environment with zapm installed. This scenario is currently unsupported.
Temporary fix
Comments
APAR Information
APAR number
OA59793
Reported component name
Z APM CONNECT
Reported component ID
5698ABF00
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-16
Closed date
2020-06-26
Last modified date
2020-07-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ03365
Modules/Macros
AGMDLA0E AGMDLA0F AGMYIO0E AGMYIO0F
Fix information
Fixed component name
Z APM CONNECT
Fixed component ID
5698ABF00
Applicable component levels
R610 PSY UJ03365
UP20/06/27 P F006
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSYHZ9","label":"IBM Z Application Performance Management Connect"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: