Error description
After a CANCEL command to CA-JCLCHECK EDIT macro !JCK , DSC abends with U3999 @@@ UNEXPECTED TBLH RETURN-CODE error.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Data Set Commander DSC V9.1 * **************************************************************** * PROBLEM DESCRIPTION: AFTER A CANCEL COMMAND TO CA-JCLCHECK * * EDIT MACRO !JCK , DSC MSL ABENDS WITH * * "U3999 @@@ UNEXPECTED TBLH RETURN-CODE" * * * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** A "CANCEL" command to CA-JCLCHECK EDIT macro !JCK , causes a FREEMAIN to a DSC control block from a storage sub-pool 16 , resulting in an MSL user ABEND with message: "U3999 @@@ UNEXPECTED TBLH RETURN-CODE" .
Problem conclusion
All DSC dynamic storage, previously allocated from sub-pool 16, is now allocated from sub-pool 22 . CA-JCLCHECK EDIT macro !JCK no longer causes a DSC MSL user ABEND .
Temporary fix
Comments
APAR Information
APAR number
OA59570
Reported component name
DATA SET COMMAN
Reported component ID
5698A8100
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-05-13
Closed date
2020-06-07
Last modified date
2020-07-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ03147
Modules/Macros
IQIEDIT1 IQIEDIT2 IQIEDIT3 IQIEDIT4 IQIEDT2S IQIEDT3S IQIMAIN IQIMSL IQIVIEW1 IQIVIEW2 IQIVIEW3 IQIVIEW4
Fix information
Fixed component name
DATA SET COMMAN
Fixed component ID
5698A8100
Applicable component levels
R910 PSY UJ03147
UP20/06/09 P F006
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.