IBM Support

OA59513: IEC028I RC8 (S/837-08) ISSUED WHEN 5 VOLUMES ARE SPECIFIED INSTEAD OF IEC030I (S/B37-4)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • When 5 volumes are specified in a volume list, an S837-8 is
    received rather than a S/B37-4.  If 4 or 6 volumes are
    specified, the expected S/B37-4 is received.
    

Local fix

  • BYPASS/CIRCUMVENTION:
    Increase the volume count or list additional volsers.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All                                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Eliminate confusion between ABEND837-08 and ABENDB37-04      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Message IEC028I will be updated to clarify differences between
    the ABENDs
    Following Text replaces the 837-08 text.
    Proposed Text for IEC028I
    =========================
    This condition can occur under the following conditions:
    - JFCB is full - exactly 5 Volumes coded.(JFCB can only hold 5
    Volume Serial Numbers)
    - JFCB and JFCB Extension(s) are full. Each Extension can hold
    15 Volume Serial Numbers, so the
      error will appear after 20,35,etc. Volumes are used.
    - This error can also occur if an OPEN TYPE=J macro is used to
    open the data set after the Volume
      Serial Number is changed and the JFCB is not updated in the
    SWA because bit 4 of the JFCBTSDM field
      of the JFCB is set to one.
    - If this error occurs while the system is reading a multivolume
    tape data set and this abend message
      is preceded by one of the following messages: IEC709I,
    IEC710I, IEC711I, or IEC712I, then the next
      Volume Serial Numbers to process was provided via the LABAN
    (Label Anomaly Tape Installation Exit) but
      either this Volume Serial could not be enqueued or no JFCB
    Extension is available to add the Volume.
    
    Specify more Volume Serial Numbers, or a larger Volume Count in
    the VOL
    parameter of the DD statement. See z/OS MVS JCL User's Guide for
    a description of the rules for
    coding Volume Count.
    
    It should be noted this error differs from IEC030I B37-04 as it
    indicates the JFCB and/or Extension(s)
    are full verses the no space available on the current Volume(s).
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA59513

  • Reported component name

    DATA MGMT SUPPO

  • Reported component ID

    5695DF107

  • Reported release

    230

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-04-29

  • Closed date

    2020-05-27

  • Last modified date

    2020-05-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Publications Referenced
SA38067430    

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date: