A fix is available
APAR status
Closed as new function.
Error description
CDP v2.1 2020 2Q CONTINUOUS DELIVERY UPDATE: Main Feature: - DCOLLECT log support. - CICS 5.5 currency support. - SMF 119 (TCP/IP) subtypes 94-98 (OpenSSH events) records support. - SMF 123 (z/OS Connect EE) subytype 1 version 2 record support. - SMF 115 (MQ) subtype 1 record updated to the latest MQ level: QJST section update. - Authenticate to Db2 via passticket. - Support sending logs to Splunk without requiring IZOA. - Support RMF III RMF SYSSUM, USAGE and SPACEG reports. - Configuration Tool supports DEFINE TABLE statements in the policy file. Key Defects Fixed: - SDE throws error messages when a date field has null value. - SDE may fail if definition files were created on laptop and uploaded to z/OS via FTP. - ESPIE exit doesn't work when ZIIPOFFLOAD=NO. - Auto qualify in UI config tool needs to default to system instead of none. - Addressing partial record issue in log. - Fix conflicting with DDS's cache refreshing. - Log Forwarder stops collecting syslog data on a random basis. A recycle of the Log Forwarder is required to restart data flow.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Common Data Provider for z * * Systems v2.1. * **************************************************************** * PROBLEM DESCRIPTION: CDP v2.1 2020 2Q CONTINUOUS DELIVERY * * UPDATE: * * * * Main Feature: * * - DCOLLECT log support. * * - CICS 5.5 currency support. * * - SMF 119 (TCP/IP) subtypes 94-98 * * (OpenSSH events) records support. * * - SMF 123 (z/OS Connect EE) subytype 1 * * version 2 record support. * * - SMF 115 (MQ) subtype 1 record updated * * to the latest MQ level: * * QJST section update. * * - Authenticate to Db2 via passticket. * * - Support sending logs to Splunk * * without requiring IZOA. * * - Support RMF III RMF SYSSUM, USAGE and * * SPACEG reports. * * - Configuration Tool supports DEFINE * * TABLE statements in the policy file. * * * * Key Defects Fixed: * * - SDE throws error messages when a date * * field has null value. * * - SDE may fail if definition files were * * created on laptop and uploaded to z/OS * * via FTP. * * - ESPIE exit doesn't work when * * ZIIPOFFLOAD=NO. * * - Auto qualify in UI config tool needs * * to default to system instead of none. * * - Addressing partial record issue in * * log. * * - Fix conflicting with DDS's cache * * refreshing. * * - Log Forwarder stops collecting syslog * * data on a random basis. A recycle of * * the Log Forwarder is required to * * restart data flow. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** - SDE throws error messages when a date field has null value. SDE needs to be updated to suppress the confused message HBO0352I when a date field has zero value. - SDE may fail if definition files were created on laptop and uploaded to z/OS via FTP. If a definition member is created on laptop and upload to z/OS by FTP (ascii mode), an empty row can become a null record (record length is zero) which will cause failure parsing the related definitions with error message HBO0049I in HBOOUT of SDE log. - ESPIE exit doesn't work when ZIIPOFFLOAD=NO. The ESPIE exit is not enabled correctly on gather TCB after multi-thread is introduced. - Auto qualify in UI config tool needs to default to system instead of none. When the customer streams data from several datasources of a single LPAR with default of none for auto qualify, logstash will report data source already exists which causes stream unsuccessful. - Addressing partial record issue in log. Data Streamer will discard the partial record during split which will cause the error message HBO6085E and data lost. - Fix conflicting with DDS's cache refreshing. If the LF sends a request to DDS at the same time as the RMF III interval refresh, due to a limitation of RMF III, sometimes CDP will gather data from the next time interval which causes data loss. - Log Forwarder stops collecting syslog data on a random basis. A recycle of the Log Forwarder is required to restart data flow. When the dataspace wraps, there will be a null data section generated at the end of dataspace which makes the program pause in a loop causing the current collection of data to be lost.
Problem conclusion
Temporary fix
Comments
×**** PE20/06/16 FIX IN ERROR. SEE APAR OA59790 FOR DESCRIPTION
APAR Information
APAR number
OA59242
Reported component name
CDP BASE
Reported component ID
5698ABJ00
Reported release
210
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-03-12
Closed date
2020-05-11
Last modified date
2020-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ02890
Modules/Macros
HBO2CCMF HBO2CD41 HBO2CD42 HBO2CD51 HBO2CD52 HBO2CD53 HBO2CD54 HBO2CD55 HBO2CD56 HBO2CDIC HBO2CIST HBO2COMP HBO2OMEG HBO2S030 HBO2S042 HBO2S070 HBO2S078 HBO2S104 HBO2S113 HBO2S30A HBO2S30O HBO2S42V HBO2S702 HBO2TS77 HBO4CICS HBOA2DUN HBOAKCUN HBOAKDUN HBOAKZUN HBOAPMUN HBOCCORN HBOCCORY HBOCCSV HBOCDEDS HBOCDEUI HBOCFGA HBOCFGT HBOCFPSH HBOCHGP HBODEPS HBODS001 HBODSDBG HBODSPRO HBODSRAW HBOENCSH HBOFLGX0 HBOGDSDL HBOGLMSG HBOGTDBG HBOIMS HBOJBCO2 HBOJBCOL HBOJBDC2 HBOJBDCO HBOJBIM2 HBOJBIMS HBOJCOLL HBOLDCOL HBOLGXA0 HBOLGXB0 HBOLGXC0 HBOLLSMF HBOLOGPR HBOMDBG HBOMUESH HBONETV HBOPASDI HBOPBLVL HBOPCDBI HBOPCGAA HBOPCGB1 HBOPCGB2 HBOPCGCM HBOPCGCW HBOPCGGC HBOPCGGF HBOPCGGP HBOPCGGX HBOPCGJA HBOPCGJC HBOPCGJE HBOPCGLO HBOPCGLW HBOPCGNN HBOPCGNO HBOPCGO1 HBOPCGO2 HBOPCGO3 HBOPCGO4 HBOPCGP1 HBOPCGP2 HBOPCGPA HBOPCGPC HBOPCGPF HBOPCGPN HBOPCGPP HBOPCGRC HBOPCGSF HBOPCGSM HBOPCGSW HBOPCGWD HBOPCGXC HBOPCGXF HBOPCGXI HBOPCGXS HBOPCGXT HBOPCGXV HBOPCGZA HBOPCGZC HBOPCGZG HBOPCGZM HBOPCGZP HBOPCGZS HBOPCGZZ HBOPCIBM HBOPCICP HBOPCMAA HBOPCMCR HBOPCMEV HBOPCMFP HBOPCMRN HBOPCMSC HBOPCMSP HBOPCMST HBOPCMSU HBOPCMSV HBOPCMZZ HBOPCOAS HBOPCOB2 HBOPCOBI HBOPCOBU HBOPCOCF HBOPCOCR HBOPCOCS HBOPCODB HBOPCODI HBOPCOHA HBOPCOIT HBOPCOLL HBOPCOLX HBOPCOME HBOPCOMM HBOPCOMR HBOPCOOT HBOPCORE HBOPCORX HBOPCOSF HBOPCOST HBOPCOUR HBOPCOUT HBOPCPRE HBOPCXAA HBOPCXCA HBOPCXCC HBOPCXCT HBOPCXFC HBOPCXFI HBOPCXIC HBOPCXID HBOPCXLD HBOPCXLO HBOPCXNN HBOPCXNU HBOPCXO1 HBOPCXO2 HBOPCXO3 HBOPCXO4 HBOPCXPX HBOPCXSE HBOPCXUS HBOPCXVA HBOPCXVR HBOPDE HBOPDELO HBOPDERE HBOPDERP HBOPDETA HBOPDETP HBOPDEUP HBOPDICA HBOPDICC HBOPDICD HBOPDICF HBOPDICI HBOPDICR HBOPDICS HBOPFRFA HBOPFRFL HBOPFRFM HBOPFRFN HBOPFRFT HBOPFRLX HBOPFRSA HBOPFRSL HBOPFRSN HBOPFRSS HBOPIFAQ HBOPIMS HBOPIMSD HBOPIO HBOPIO31 HBOPLIIT HBOPLIIX HBOPLILI HBOPLIOB HBOPLIPR HBOPLIRE HBOPLIST HBOPLODT HBOPLOEX HBOPLOG HBOPLOOI HBOPLOOK HBOPLOOU HBOPLOPE HBOPLOPF HBOPLOPR HBOPLOST HBOPLSMC HBOPLSPR HBOPMG HBOPMG00 HBOPMG01 HBOPMG02 HBOPMG03 HBOPMG04 HBOPMG05 HBOPMG21 HBOPMG29 HBOPMG50 HBOPMG52 HBOPMG80 HBOPMG81 HBOPMG82 HBOPNCCI HBOPNCCR HBOPNCCS HBOPNCDF HBOPNCFD HBOPOLDS HBOPPACO HBOPPAER HBOPPAEX HBOPPAFI HBOPPARS
Fix information
Fixed component name
CDP BASE
Fixed component ID
5698ABJ00
Applicable component levels
R210 PSY UJ02890
UP20/05/15 P F005
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"210","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
17 June 2020