A fix is available
APAR status
Closed as program error.
Error description
Predictive Failure Analysis (PFA) PFA_PRIVATE_STORAGE_EXHAUSTION may issue false exceptions if the model and compare processing are occurring concurrently and the compare completes first. It also may say status is successful and storage usage has not changed. You may see symptoms like the following in an HZSPRINT 10:34:01 - STATUS: EXCEPTION-HIGH Next model time 10:34:55 10:35:02 - STATUS: SUCCESSFUL AIRH224I message issued 10:36:02 - STATUS: EXCEPTION-HIGH Last model time 10:35:07
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of HBB77A0 and HBB77B0, * * exploiting the Predictive Failure * * Analysis (PFA). * **************************************************************** * PROBLEM DESCRIPTION: * * Predictive Failure Analysis (PFA) for * * PFA_PRIVATE_STORAGE_EXHAUSTION check * * issues high severity exception one * * minute than next min AIRH224I * * successful and next minute high * * severity exception again. * **************************************************************** * RECOMMENDATION: * **************************************************************** PFA issued false exception for PFA_PRIVATE_STORAGE_EXHAUSTION check when model and compare processing occurring concurrently and compare completed before modeling. This resulted in issuance of AIRH224I (no data) message when there was data and modeling was successful.
Problem conclusion
Code has been changed to eliminate timing window between compare and modeling for PFA's PFA_PRIVATE_STORAGE_EXHAUSTION check.
Temporary fix
Comments
APAR Information
APAR number
OA55587
Reported component name
Z/OS PFA
Reported component ID
5752SCPFA
Reported release
7A0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-24
Closed date
2019-07-10
Last modified date
2019-08-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA99886 UA99893
Modules/Macros
AIRPAFUP AIRHMMON AIRHMMAP AIRHMLAP AIRHMCHK AIRHMPJP AIRHMPJM
Fix information
Fixed component name
Z/OS PFA
Fixed component ID
5752SCPFA
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
01 August 2019