Error description
Customer performs the following steps: 1. created new ACF (via build) without doing a Refresh 2. recycled SA/Netview (or IPL, Manager start hot) 3. Message AOF618I NO VALID ACF MEMBER FOUND FOR xx - ACF TOKEN MISMATCH occurs. 4. F PAM,refresh,* or INGAMS REFRESH CFG=* resolves that issue 5. adding a new APL into the Policy and run Build and refresh. Refresh complains about the new member with message AOF784I AUTOMATION CONTROL FILE MEMBER Z9RJAAPL IS EMPTY OR DOES NOT EXIST. yet the member is ok.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All SA z/OS V3R3 and V3R4 customers. * **************************************************************** * PROBLEM DESCRIPTION: When msgAOF618I has been issued to * * indicate an ACF load failure, it is * * possible that while wtor msgAOF602D is * * waiting for a reply an attempt to * * refresh the ACF will leave the ACF * * allocated as a DSIPARM OPER-DS dataset. * * When this occurs then any new members * * added to the ACF cannot be identified * * and is normally followed by msgAOF784I * * indicating which member. * **************************************************************** * RECOMMENDATION: * **************************************************************** The ACF should not be left in the DSIPARM concatenation as an OPER-DS dataset following a load failure.
Problem conclusion
Rexx routine AOFRANT3 has been changed to ensure the ACF is removed as an OPER-DS dataset from the DSIPARM concatenation following a load failure.
Temporary fix
Comments
APAR Information
APAR number
OA44757
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
340
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-03-13
Closed date
2014-03-25
Last modified date
2014-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA72945 UA72946
Modules/Macros
AOFRANT3
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"340","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]