A fix is available
APAR status
Closed as program error.
Error description
CLNASTRB entry point address is stored as A(X'80000000'+CLNASTRB) in IGWLHT00 which assumes that CLNASTRB is 31bit addressing when it is in fact 64bit. Attempting to reference reg 15 containing the address of CLNASTRB in 64bit mode results in referencing unallocated storage and the 0C4. This error manifests as recursive 0C4 ABENDS at IGWLHAJB+116. ADDITIONAL KEYWORD: PDSE/K
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Queue validation routine program checks when * * called as if 31 bit routine but actually 64 * * bit. This can only occur when a queue * * updata operation is interrupted. * **************************************************************** * PROBLEM DESCRIPTION: See users affected. * **************************************************************** * RECOMMENDATION: * **************************************************************** Change IGWLHT00 to correctly identify addressing mode for CLNASRTB.
Problem conclusion
See Problem Summary.
Temporary fix
Comments
APAR Information
APAR number
OA34764
Reported component name
EXTENDED DATA S
Reported component ID
5695DF115
Reported release
B10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-10-28
Closed date
2010-11-30
Last modified date
2014-03-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA58122 UA58123 UA58124
Modules/Macros
IGWLHT00
Fix information
Fixed component name
EXTENDED DATA S
Fixed component ID
5695DF115
Applicable component levels
RA10 PSY UA58122
UP11/01/28 P F101
RB10 PSY UA58123
UP11/01/28 P F101
RC10 PSY UA58124
UP11/01/28 P F101
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: