Direct link to fix
APAR status
Closed as program error.
Error description
As part of the fix for JR64362 when you attempt to open an application in Integration Designer if a referenced snapshot is archived, it gets restored.
Local fix
Problem summary
When you open a Workflow Center project in IBM Integration Designer that depends on a toolkit snapshot that is archived, the snapshot is automatically restored. This may not be the desired behavior. PRODUCT AFFECTED: IBM Business Automation Workflow
Problem conclusion
A fix is available that provides a configuration option to enable or disable the auto restore behavior introduced by APAR JR64362. Set the following configuration in the 100Custom.xml: <server> <restore-archived-snapshots-on-iid-import merge="replace">true</restore-archived-snapshots-on-iid-import> </server>
Temporary fix
Comments
APAR Information
APAR number
JR64478
Reported component name
BUS AUTO WORKFL
Reported component ID
5737H4100
Reported release
L00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-12-23
Closed date
2022-02-01
Last modified date
2022-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"21.0.2","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
24 August 2022