APAR status
Closed as program error.
Error description
When you try to create the IBM Integration Designer unit test environment and database type is DB2, the BPMConfig -create command might fail with SQL0554N, and the database scripts do not get generated as the database was not created correctly. Since the command includes the -s parameter, and DB2 does not allow permissions to be granted to the user itself, db2cmd /c /w /i db2 -stf "./createDatabase_ECM.sql" the execution of createDatabase_ECM.sql stops when an error is encountered. PRODUCTS AFFECTED: IBM Business Automation Workflow
Local fix
Problem summary
No additional information is available.
Problem conclusion
A fix is available or will be available that will tolerant the SQL0554N error.
Temporary fix
Comments
APAR Information
APAR number
JR64092
Reported component name
BUS AUTO WORKFL
Reported component ID
5737H4100
Reported release
K00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-20
Closed date
2023-11-20
Last modified date
2023-11-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"20.0.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]