Direct link to fix
APAR status
Closed as program error.
Error description
The following exception occurs when the runtime emits a Business event containing null data: BusinessEvent E com.ibm.bpm.bui.emitter.event.BusinessEventGenerator generateEvent Error while building bpmn business event. java.lang.NullPointerException: value must not be null at org.apache.johnzon.core.JsonStringImpl.(JsonStringImpl.java:32) at org.apache.johnzon.core.JsonObjectBuilderImpl.add(JsonObjectBuil derImpl.java:43) at com.ibm.bpm.bui.emitter.event.BusinessEventGenerator.handleData( BusinessEventGenerator.java:452) at com.ibm.bpm.bui.emitter.event.BusinessEventGenerator.generateEve nt(BusinessEventGenerator.java:275) at com.lombardisoftware.server.monitor.MonitorEventJSONWriter.forma t(MonitorEventJSONWriter.java:156) at com.lombardisoftware.server.monitor.MonitorEventJSONWriter.forma t(MonitorEventJSONWriter.java:45) at com.ibm.bpm.def.wle.formatter.WleJsonFormatter.format(WleJsonFor matter.java:42) at com.ibm.bpm.def.wle.formatter.WleJsonFormatter.format(WleJsonFor matter.java:10) at com.ibm.bpm.def.impl.EventPointImpl.createSerializedDefEvent(Eve ntPointImpl.java:158) at com.ibm.bpm.def.impl.EventPointImpl.access$100(EventPointImpl.ja va:44) at com.ibm.bpm.def.impl.EventPointImpl$1.run(EventPointImpl.java:19 0) at com.ibm.ws.uow.embeddable.EmbeddableUOWManagerImpl.runUnderCurre ntUOW(EmbeddableUOWManagerImpl.java:987) at com.ibm.ws.uow.embeddable.EmbeddableUOWManagerImpl.runUnderUOW(E mbeddableUOWManagerImpl.java:374) at com.ibm.bpm.def.impl.EventPointImpl.fire(EventPointImpl.java:214 )
Local fix
Set the JVM property "-DuseBAIBridgeEvents=true" on all the Application cluster members and restart the cluster.
Problem summary
A NullPointerException prevents Business events to be emitted by the runtime when they contain null data.
Problem conclusion
A fix is available or will be available that ensures the business events are emitted without exception.
Temporary fix
Comments
APAR Information
APAR number
JR63651
Reported component name
BUS AUTO WORKFL
Reported component ID
5737H4100
Reported release
J00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-05-05
Closed date
2021-05-05
Last modified date
2021-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"19.0.0.1"}]
Document Information
Modified date:
21 June 2021